SuperiorFireplaces.us.com
900463-01E
29
VARIABLE REMOTE MODELS OPERATION
Continued
To activate this function, press THERMOSTAT but-
ton until the word SMART appears to the right of
temperature bulb graphic on display. Use UP/DOWN
arrow button to set desired room temperature. The
control system will cycle the fi replace on or off to
maintain selected temperature.
SMART
MAX
Figure 46 - Smart Thermostat Setting
ON
Figure 47 - Child Safety Lock-Out
CHILD SAFETY LOCK-OUT
This function lets you deactivate the remote control
buttons. It is active when the lock icon is lit on
the display.
To activate, press MODE button and UP arrow but-
ton at the same time. To deactivate, press again.
REPLACING HAND-HELD REMOTE CONTROL
ONLY
If your remote ever needs to be replaced you will
not need to replace the receiver.
To program receiver with a new hand-held remote,
insert a small pin or paper clip into hole on receiver
face plate marked PRG. The receiver will beep 3
times to indicate it is ready to accept a new remote
transmitter. Press the ON/OFF button on your re-
mote and the receiver will beep 4 times to confi rm
it receives commands from the new remote.
Figure 48 - Programing Remote Control to
Receiver
Figure 49 - Correct Pilot Flame Pattern
Figure 50 - Incorrect Pilot Flame Pattern
Pilot Burner
Thermocouple
Thermocouple
Pilot Burner
Check pilot fl ame pattern and burner fl ame pat-
terns often.
PILOT FLAME PATTERN
Figure 49
shows a correct pilot fl ame pattern.
Figure 50
shows an incorrect pilot fl ame pattern.
The incorrect pilot fl ame is not touching the ther-
mocouple. This will cause the thermocouple to
cool. When the thermocouple cools, the appliance
will shut down.
If pilot fl ame pattern is incorrect, as shown in
Figure 50
• turn appliance off (see To Turn Off Gas to Appli-
ance,
Page 27
INSPECTING BURNERS
• see Troubleshooting,
Page 32
NOTE
: The pilot fl ame on natural gas units will
have a slight curve, but fl ame should be blue and
have no yellow or orange color.
To
Program
Receiver
ON REMOTE OFF
PRG