Frequency Band: 2.402-2.480 GHz

11.Environmental temperature for operation: 10°C-40°C(50°F -104°F)

12. Environmental humidity for operation:

85%RH

13. Environmental temperature for storage and transport:-20°C-55°C(-4°F-131°F)

14. Environmental humidity for storage and transport:

85%RH

15. Environmental pressure: 80kPa-105kPa

16. Battery life: more than 500 measurements on a full charge, the battery can maintain the performance characteristics for a

minimum of 300 charge cycles

17.The blood pressure measurement system includes accessories: pump, valve, cuff, and sensor.

Note:

These specifications are subject to change without notice.

GENERAL SAFETY AND PRECAUTIONS

1. Read all of the information in the User Guide and other provided instructions before operating the unit.

2. Consult your physician for any of the following situations:

a)The application of the cuff over a wound or inflamed area.

b)The application of the cuff on any limb with intravascular access or therapy, or an arteriovenous (A-V) shunt.

c)The application of the cuff on the arm on the side of a mastectomy.

d)Simultaneous use with other medical monitoring equipment on the same limb.

e)The blood circulation of the user needs to be checked.

3. Do not use this product in a moving vehicle as this may result in inaccurate measurements.

4. Blood pressure measurements determined by this product are equivalent to those obtained by professional healthcare

practitioners using the cuff/stethoscope auscultation method within the limits prescribed by the American National Standard,

Electronic or Automated Sphygmomanometer.

5. If you are using a smart phone to operate the device and a phone call comes in during the measurement, the measurement

process will be terminated automatically. It is thus recommended that the phone be set in Airplane mode during measurement

to avoid interrupting the measurement.

6. If an Irregular Heartbeat (IHB) is detected during the measurement procedure, the IHB symbol will be displayed. Under this

condition, the Wireless Blood Pressure Monitor can keep functioning, but the results may be inaccurate. Please consult your

physician for accurate assessment.

The IHB symbol will be displayed under 2 sets of circumstances:

1)The coefficient of variation (CV) of pulse period >25%.

2)The difference of adjacent pulse period is

0.14s and more than 53 percent of the total number of pulses readings falls

within this definition.

7. Please do not use any cuff other than that supplied by the manufacturer as this may result in inaccurate measurements.

8. For information regarding potential electromagnetic or other interference between the Wireless Blood Pressure Monitor and

other devices together with advice regarding avoidance of such interference, please see ELECTROMAGNETIC

COMPATIBILITY INFORMATION. It is suggested that the Wireless Blood Pressure Monitor should be operated at least 10

metres away from electric or wireless devices (e.g. routers, microwave oven, etc.)

9. If the blood pressure measurement (systolic or diastolic) is outside the rated range specified in part SPECIFICATIONS, the

app will immediately display a technical alarm on the screen. In this case, repeat the measurement ensuring that the proper

measurement procedures are followed and/or consult with your medical professional.The technical alarm is preset in the

factory and cannot be adjusted or inactivated. This technical alarm is assigned as low priority according to IEC 60601-1-8. The

technical alarm does not need to be reset.

Summary of Contents for BP3

Page 1: ...SET UP REQUIREMENTS 2 SET UP PROCEDURES 2 SPECIFICATIONS 4 GENERAL SAFETY AND PRECAUTIONS 4 BATTERY HANDLING AND USAGE 4 TROUBLESHOOTING 4 CARE AND MAINTENANCE 4 WARRANTY INFORMATION 4 EXPLANATION OF...

Page 2: ...using a technique in which an inflatable cuff is wrapped around the upper arm The measurement range of the standard cuff circumference is 8 21 32 to 14 3 16 22cm 36cm Note Consult your physician for...

Page 3: ...or Status Bluetooth Indicator Waiting to connect No light Connected and measuring Steady green light Measurement completed and Device far away from the monitor Extinguishing green light MEASUREMENT PR...

Page 4: ...y remove it from the monitor and clean it with a moistened cloth Do not rinse the monitor or cuff with running water Press the button at any time to interrupt a measurement Note Physical activity eati...

Page 5: ...one call comes in during the measurement the measurement process will be terminated automatically It is thus recommended that the phone be set in Airplane mode during measurement to avoid interrupting...

Page 6: ...dicator Charging Flashing green light Fully charged Steady green light Low battery Flashing red light for a few seconds Abnormal state Steady red light Do not change the battery If the battery can no...

Page 7: ...gent 6 The monitor can maintain the safety and performance characteristics for a minimum of 10 000 measurements or three years of usage and the cuff integrity is maintained after 1 000 open close cycl...

Page 8: ...andards Apple is not responsible for the operation of this device or its compliance with safety and regulatory standards Please note that the use of this accessory with iPod iPhone or iPad may affect...

Page 9: ...conditi ons 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device This product is approved in...

Page 10: ...ustomer or the user of the BP3L should assure that it is used in such an environment IMMUNITY test IEC 60601test level Compliance level Electromagnetic environment guidance Electrostatic discharge ESD...

Page 11: ...o any part of the BP3L including cables than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter Recommended separation distance 80 MHz to 8...

Page 12: ...by maintaining a minimum distance between portable and mobile RF communications equipment transmitters and the BP3L as recommended below according to the maximum output power of the communications equ...

Reviews: