CANopen encoder
14
Index S-Idx Name
Type,
access
default value
Description
100C 0
Guard time
u16, rw
0
This object contains the 'guard time' in
milliseconds�
100D 0
Life time factor
u8, rw
0
This object contains the life time factor
parameter� The life time factor multiplied
with the guard time results in the life time
for the guarding protocol�
1010
Store
parameters
This object is used to write the
parameters to the non-volatile memory�
0
Number of sub
indices
u8, ro
1
1
Store all
parameters
u32, rw
"save"
To write the parameters to the non-
volatile memory the word "save" has to
be sent to the corresponding node�
Most significant word
Least significant word
ASCII
e
v
a
s
Hex value
65h
76h
61h
73h
1011
Restore
parameters
The object is used to restore the factory
settings�
0
Number of sub
indices
u8, ro
1
1
Restore all
parameters
u32, rw
"load"
To restore the factory settings the
word "load" has to be sent to the
corresponding node� When the
parameters have been restored, please
check the parameters before the store
command is executed again� The
restored parameters only become active
after a reset or power up�
Most significant word
Least significant word
ASCII
d
a
o
l
Hex value
64h
61h
6Fh
6Ch
Summary of Contents for RM8004
Page 33: ...UK CANopen encoder 33...
Page 34: ...CANopen encoder 34...
Page 35: ...UK CANopen encoder 35...