5.3 Features of the unit
• The unit versions are offered with different probe lengths�
• Point level selectable by the installation length
(→ 6)
�
• Parameter setting using the teach button
(→ 9.1)
or via IO-Link
(→ 9.2)
�
• The unit has two switching outputs:
-Output OUT1 is assigned to the process value "Level"�
-Output OUT2 can be assigned to the process value "Level" or "Temperature"�
•
Adjustment function (empty and full adjustment) to the medium to be detected.
• Defined state in case of a fault
(→ 9.2.4)
5.3.1 IO-Link
The device has an IO-Link communication interface which requires an IO-Link
capable module (IO-Link master).
The IO-Link interface enables direct access to the process and diagnostic data
and provides the possibility to set the parameters of the unit during operation�
In addition, communication is possible via a point-to-point connection with a USB
IO-Link master�
The IODDs necessary for the configuration of the unit, detailed information about
process data structure, diagnostic information, parameter addresses and the
necessary information about the required IO-Link hardware and software can be
found at www�ifm�com�
5.4 Application examples
1
2
3
1: Overflow protection in a supply tank for coolant emulsion�
2: Leakage monitoring in the overflow vessel of a hydraulic power unit�
3: Minimum level monitoring�