background image

5

UK

Sensitivity setting (1-point teach)

Useful if the object is highly transparent or with thin film� However, excess gain is 

less than using the 2-point teach�

a) Output switched ON when object detected

1

 

Remove

 object

 

Press [OUToff] for 2 s�

 

>

Yellow LED flashes

 

Release pushbutton

 

>

Sensitivity measurement carried out (1 s)

 

>

Yellow LED flash rate doubles

2

 

Press and release [OUToff]

 

>

Sensitivity measurement carried out (1 s)

 

>

Yellow LED out� Programming complete�

Sensitivity setting unsuccessful:

 

>

The yellow LED flashes fast, 8Hz� Cause:

•  Signal from prismatic reflector unstable (e�g� in case of vibration)
•  Max� setting time 15  min� exceeded 

 

>

Unit ignores setting attempt

b) Output switched OFF when object detected

Proceed as above, but:

 

Each time press [OUTon]�

 

>

Yellow LED on�