5
UK
Sensitivity setting (1-point teach)
Useful if the object is highly transparent or with thin film� However, excess gain is
less than using the 2-point teach�
a) Output switched ON when object detected
1
►
Remove
object
►
Press [OUToff] for 2 s�
>
Yellow LED flashes
►
Release pushbutton
>
Sensitivity measurement carried out (1 s)
>
Yellow LED flash rate doubles
2
►
Press and release [OUToff]
>
Sensitivity measurement carried out (1 s)
>
Yellow LED out� Programming complete�
Sensitivity setting unsuccessful:
>
The yellow LED flashes fast, 8Hz� Cause:
• Signal from prismatic reflector unstable (e�g� in case of vibration)
• Max� setting time 15 min� exceeded
>
Unit ignores setting attempt
b) Output switched OFF when object detected
Proceed as above, but:
►
Each time press [OUTon]�
>
Yellow LED on�