background image

7

UK

Electronic lock

 

To lock press [OUTon] and [OUToff] together for 10���20 s�

 

>

Acknowledgement: LED status (yellow) inverted�

 

To unlock repeat procedure�

Operation

Check whether the unit operates correctly� Display by LEDs�

Yellow LED on

OUT output is switched 

Red LED on

Limit of the switch point compensation reached:  

e�g� unit out of alignment; lens / reflector dirty  

FC output switched 

Yellow LED flashes

2 Hz: internal fault�
8 Hz: sensitivity setting incorrect�
(OUT output is not switched)�

Switch point compensation

The O5G501 unit has no switch point compensation�

Once the sensitivity setting has been carried out, the unit automatically compen-

sates for switch point drift�

The red LED lights and the output FC “Function check output” switches as soon 

as the limit of the switch point compensation is reached� At this point the lens of 

the unit and the prismatic reflector need to be cleaned (→ Maintenance).

After cleaning new programming of the unit is carried out automatically� To do so, 

no object is allowed in the beam�

Maintenance

Keep the lens of the unit and the prismatic reflector free from contamination� For 

cleaning do not use any solvents or cleaning agents which could damage the 

plastic�