Process and dialogue module ecomatDisplay CR1058, CR1059
38
NOTE!
No protection rating when service cover is open and no ESD protection
on accessible contacts inside
> Damage to the device possible
►
Before opening, clean the area around the service cover�
►
Remove the service cover on the back of the unit�
►
Protect inside of device, sealing areas and sealing of the service
cover from soiling and humidity�
►
When changing the battery, take ESD precautions�
►
Remove the battery and replace it with a new one� Observe the
polarity: positive pole on top
►
Check sealing areas and sealing for soiling and clean, if necessary�
►
Screw on service cover until end stop is reached to restore
protection rating�
►
Reset system time via device set-up or application (see
programming manual ecomatDisplay).
Disposal of used batteries
8.2 Cleaning the display surface
Unsuitable cleaning agents and chemicals can damage the display surface�
The following agents are not suited for cleaning the display:
●
chemicals dissolving plastics such as methylated spirit, benzine, thinner,
alcohol, acetone or ammonia
●
paper towels, crepe paper etc�
●
abrasive cleaners etc�
●
polish or wax
►
Clean the device from dirt using a soft, chemically untreated and dry cloth�
►
In case of heavy dirt, use a damp cloth�
Micro-fibre cloths without chemical additives are recommended�