Process and dialogue module ecomatDisplay CR1058, CR1059
22
5.9.1 Short-circuit protection
NOTE!
The USB interface (M12 connector) is not protected against short
circuits with a live wire outside the following voltage ranges:
+5 V DC -0.3...6.0 V DC (pin 1)
–Data -0.3...3.6 V DC (pin 2)
+Data -0.3...3.6 V DC (pin 3)
ID -0.3...3.6 V DC (pin 4)
A short circuit will destruct the USB interface�
5.10 Selection of loudspeakers
For an optimum audio output 8
Ω loudspeakers
have to be used�
6 Set-up
6.1 General
The factory setting of the device shows a demo application� By means of the
installed recovery app any suitable firmware version can be loaded to the device�
Factory settings:
IP adress: 192�168�82�247
Subnet mask: 255�255�255�0
Gateway IP address: 192�168�82�1
The user is responsible for the safe function of the application programs
which he created himself� If necessary, an approval by corresponding
supervisory and test organisations according to the national regulations
must be carried out additionally�