UK
ClassicController CR0053
21
7.4 Output characteristics
ifm electronic gmbh
●
Friedrichstraße 1
●
45128 Essen We reserve the right to make technical alterations without prior notice!
14.06.2016
CR0053 / page 7
CR0053
Output characteristics
Control systems
Q00...03
Q08...11
Digital/ PWM outputs
Protective circuit for inductive
loads
integrated
Diagnosis wire break
via current feedback
Diagnosis short circuit
via current feedback
Digital output (B
H
and B
H/L
)
Switching voltage
8...32 V DC
Switching current
0.01...2 A / 0.02...4 A
(of which 4 with H-bridge function)
PWM output (PWM)
Output frequency
20...250 Hz (per channel)
Pulse/pause ratio
1...1000 ‰ (adjustable via software)
Resolution
1 ‰
Switching current
0.01...2 A / 0.02...4 A
(of which 4 with H-bridge function)
Current-controlled output (PWM
I
)
Output frequency
20...250 Hz (per channel)
Control range
0.01...2 A / 0.02...4 A
Setting resolution
1 mA
Control resolution
1 mA / 2 mA
Load resistance
≥
6
Ω
/
≥
3
Ω
(at 12 V DC)
≥
12
Ω
/
≥
6
Ω
(at 24 V DC)
Accuracy
± 2 % FS (for inductive loads)
Q04...07
Q12...15
Digital/ PWM outputs
Protective circuit for inductive
loads
Integrated
Diagnosis wire break
via current feedback
Diagnosis short circuit
via current feedback
Digital output (B
H
)
Switching voltage
8...32 V DC
Switching current
0.02...3 A
PWM output (PWM)
Output frequency
20...250 Hz (per channel)
Pulse/pause ratio
1...1000 ‰ (adjustable via software)
Resolution
1 ‰
Switching current
0.02...3 A
Current-controlled output (PWM
I
)
Output frequency
20...250 Hz (per channel)
Control range
0.02...3 A
Setting resolution
1 mA
Control resolution
2 mA
Load resistance
≥
4
Ω
/ (at 12 V DC)
≥
8
Ω
/ (at 24 V DC)
Accuracy