Installation instructions CANwireless CR3130/CR3131
28
0x3006 A
Socket Auto
Connect
Protocol/WLAN
(Dynamic
Connect,
Volatile)
UInt8
rw
0
0: TCP
1: UDP
0x3006 B
SPP Auto
Connect MAC/
Bluetooth
(Dynamic
Connect,
Volatile)
String
rw
0
Bluetooth MAC for Dynamic
Connect to Volatile Address
0x3006 C
Scan Bluetooth
Ready Flag
UInt8
ro
0
0: not ready/not started
1: ready
0x3006 D
Save Pairing
Ready Flag
UInt8
ro
0
0: not ready/not started
1: ready
0x3007 1
Bluetooth
MAC Address
(Bluetooth
Address)
String
ro
0
Own Bluetooth Address
0x3007 2
WLAN MAC
Address
String
ro
0
Own WLAN MAC Address
0x3007 3
Firmware
Version Radio
Module
String
ro
0
Firmware Version of Radio
Module, e�g� 1�0�0�5
0x3008 1
Request WLAN/
Bluetooth Info
Enable
UInt8
rw
0
0: Disabled
1: Enabled
0x3008 2
WLAN Enable
UInt8
rw
1
0: Disabled
1: Enabled
0x3008 3
Blueooth Enable UInt8
rw
1
0: Disabled
1: Enabled
0x3333 2
Clamp 30
UInt8
ro
0
Voltage of the power supply
measured in V�
This parameter is read-only�
0x3333 3
CANopen NMT
state
UInt8
ro
0
0: Initialization
5: Operational