Installation instructions CANwireless CR3130/CR3131
18
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen We reserve the right to make technical alterations without prior notice!
23�09�2016
CR3130 / page 2
CR3130
Technical data
Control systems
Software
Device confi guration
ifm maintenance tool or CODESYS with EDS fi le
Remark
For more information see www.ifm.com → CR3130
Mechanical data
Ambient temperature
-30���75 °C
Protection rating
IP 67
Housing material
polyamide (black)
Weight
0�060 kg
Test standards and regulations
CE
EN 60950-1
EN 301489-1 V1�9�2
EN 301489-17 V2�2�1
EN 61000-6-2
EN 61000-6-3
EN 300328 V1�9�1
EN 301893 V1�8�1
E1
UN/ECE-R10
FCC
FCC Part 15/47 CFR Conducted Limits
FCC Part 15/47 CFR Radiated Emission Limits
regarding Part 15 of the FCC rules (Class B digital devices)
Wiring
CAN / supply
M12 connector, 5 poles
4
2
1
3
5
1
2
3
4
5
GND
U
B
Not connected
CAN_H
CAN_L
Ground
Supply
Not connected
CAN interface (high)
CAN interface (low)
RS-232
M12 connector, 5 poles
4
2
1
3
5
1
2
3
4
5
GND
Not connected
DSR
RxD
TxD
Ground
Not connected
Data Set Ready (boot)
RS-232 receive (input)
RS-232 transmit (output)
Remarks
1)
for CAN messages and 1 MBit/s
2)
for transmission of a single CAN message