23
UK
8.1.6 Run mode
After set-up via a "Guided Teach", the sensor is put to the Run mode� The unit is
ready for operation�
It continually detects profiles and compares them to the taught reference profile
based on the set switching threshold�
The result (good part/bas part) is provided:
• Visually via the display:
-good part: matching value indicated in green
if matching value ≥ switching threshold
-bad part: matching value indicated in red
if matching value < switching threshold
• Visually via the switching status indication: colours according to the set
function
• Switching output: Depending on the set function, OUT1 is switched or not
switched�
90
%
100
%
1
xxxyyyzzz
1: status line
In the status line of the display, the measurement state is indicated:
•
Running: → undisturbed operation
•
Warnings / errors: → see error table(→ 13 Troubleshooting)
�