32
11.2.1 Submenu
[
Configuration
]
[Trigger Mode]
Set operating mode
►
Confirm the parameter with [ENTER] and select one of the
options [CONT] / [TRIG] using the [Up] or [Down] button�
►
Confirm your selection by pressing [ENTER]�
> The operating mode is confirmed�
[CONT]: continuous trigger mode
[TRIG]: triggered mode
[Trigger Source]
Set the source for the trigger signal
►
Confirm the parameter with [ENTER] and select one of the
options [HW] / [PDOUT] using the [Up] or [Down] button�
►
Confirm your selection by pressing [ENTER]�
> The input signal is confirmed�
HW: Apply the input signal via pin 5� The logic levels (npn / pnp)
are defined under [Output logic]�
PDOUT: The input signal is transmitted via the IO-Link master
(IO-Link operation)�
[Trigger Delay]
Set the delay time of the trigger signal until the start of the
measurement
►
Confirm the parameter with [ENTER] and select the desired
value (0���5000 ms) using the [Up] or [Down] button�
►
Confirm your selection by pressing [ENTER]�
> The delay time is confirmed�
[Integration Time]
Set exposure time
►
Confirm the parameter with [ENTER] and select one of the
options [Auto] / [0���10 ms] using the [Up] or [Down] button�
►
Confirm your selection by pressing [ENTER]�
> The exposure time is confirmed�
For the factory setting [AUTO], the exposure time is
automatically determined and set by the sensor�A
fixed setting of the integration time may be useful if a
dark ROI situated amongst reflective surfaces is to be
reliably assessed�