Seite 38 von 72
9.3.4 "importConfig”
M e t h o d N a m e
importConfig
D e s c r i p t i o n
i m p o r t wh o l e c o n f i g ur a t i o n , wit h t he o p t i o n t o s k i p s p e c if i c p a r t s
I n p u t P a r a m e -
t e r s
1. configurat ion as one da ta -bl o b :bi nar y/ b ase6 4
2. flags whi c h parts should be loaded:
0x 0 00 1: I nc lud e G l o b al e- C on fi gu rat ion ( Na me, D escri pt i on, L ocati o n, .. . )
0x 0 00 2: I nc lud e Ne t wor k- C on figuration (IP, DHCP, ...)
0x0010: Include All Application-Configurations
O u t p u t P a r a -
m e t e r s
1 . em p t y- s t r i n g ( c om p a t ibi l i t y for classic XmlRPC-Client)
9.3.5 "exportApplication”
M e t h o d N a m e
exportApplication
D e s c r i p t i o n
e x p o r t s o n e a p p l i c a t i o n- c o n f i g
I n p u t P a r a m e -
t e r s
1. Application Index
O u t p u t P a r a -
m e t e r s
1 . a p p l i c at i on - c o n f i g a s one data-blob :binary/ base64
9.3.6 "importApplication”
M e t h o d N a m e
importApplication
D e s c r i p t i o n
imports an application-config and creates a new application with it.
The name of the application should be based on the one stored in the ex-
ported-config.
If the name should be unique, the sensor must generate an suffix in case of
a naming conflict.
The device will give a new ID, if there is an ID inside the config-data it
must be ignored.
The device will put the new application on the first free Index.
I n p u t P a r a m e -
t e r s
1. application-config as one-data-blob: binary/base64
O u t p u t P a r a -
m e t e r s
1. Index of new application
Summary of Contents for O3D303