12 Operation
12.1 Operation with single probe
The single probe is made up of one individual rod. Operation with a single probe is
suited for the detection of aqueous media, in particular of heavily soiled aqueous
media.
For correct function with single probe, the unit needs a sufficiently large
metal launching surface / launching plate. It is necessary for transferring
the microwave pulse to the tank with optimum transmission power.
For installation in closed metal tanks / metal bypass pipes, the tank lid
/ upper pipe section serves as a launching surface. For installation in
open metal tanks, tanks made of plastic or metal tanks with plastic lids
a sufficiently large fixing plate, a metal plate or similar must be used
For operation with single probe, minimum distances to tank walls and
structures in the tank must be adhered to
12.2 Operation with coaxial probe
The coaxial probe is made up of an inner probe and an outer probe pipe (coaxial
pipe). The probe is centred in the coaxial pipe by one or several spacers.
In case of operation with a coaxial probe media with a low dielectric constant (e.g.
oil and oil-based media) are detected in addition to aqueous media.
In addition, the following applies in case of operation with coaxial probe:
• No launching plate is required.
• No minimum distances to tank walls and objects in the tank need to be
observed.
• No tank adjustment is necessary.
Observe the application area of the coaxial probe
.
12.3 Function check
After power-on the device is in the operating mode. It carries out its measurement
and evaluation functions and generates output signals according to the set
parameters.
►
Check whether the unit operates correctly.