17
UK
Rated insulation voltage
30 V
Output voltage at 24 V
compatible with EN 61131-2 inputs type 1,
2 and 3
Response time
response time on safety request (removal
from the enable zone): ≤ 50 ms
response time when approaching the enable
zone (enable time): ≤ 200 ms
Risk time (response time for safety-related
faults)
≤ 100 ms
Power-on delay time
5 s
Safe switch-off distance s
ar
45 mm
Operating mode
continuous operation (maintenance-free)
EMC / vibration, shock
according to IEC 60947-5-2
Application
class C to EN 60654-1
(weatherproof application)
Climate
Air pressure 80���106 kPa
Salt spray no
Height above sea level max� 2000 m
Ionising radiation not permissible
Rate of temperature change 0�5 K/min
Ambient temperature -25��60 °C for service life ≤ 87 600 h
10���40 °C for service life ≤ 175 200 h
Relative air humidity 5���95 % for service life ≤ 87 600 h
5���70 % for service life ≤ 175 200 h
Mission time T
M
(mission time)
≤ 87 600 h (10 years) at -25���60 °C and
5���95 % relative humidity
≤ 175 200 h (20 years) at 10���40 °C and
5���70 % relative humidity
Safety-related reliability
(to IEC 61508)
PFH < 2�5 x 10
-9
/ h
MTTF
d
1992 years
DC / CCF / Cat�
99 % / 100 % / 4
Protection
IP 65 / IP 67 (to EN 60529), III
Housing materials
PPE; diecast zinc