12 Troubleshooting
Problem
Possible cause
Troubleshooting
No LED display
No voltage supply
Apply voltage
Power LED flashes and
sensor does not switch
• Undervoltage
• Overvoltage
Correct the voltage
Sensor does not switch,
not even after undamping
and redamping
Sensor was brought into the
safe state (logic "0")� Cause:
• Cross fault between both
outputs A1 and A2
• Cross fault between one
output (A1 or A2) and the
supply voltage
• Error in the sensor detected
• Switch the operating voltage
off and on again
• Check wiring and connec-
tions
• Check external electronics
(e�g� PLC)
• Remove the cross fault
• Replace the unit
13 Maintenance, repair and disposal
If used correctly no maintenance and repair measures are necessary�
Only the manufacturer is allowed to repair the unit�
After use dispose of the unit in an environmentally friendly way in accordance with
the applicable national regulations�