EN
5 - ADJUSTMENT AND SETUP
Master 80 UP HyperFlexible
5 - Pag. 14 / 14
5.3.2 BAR PUSHER REPLACEMENT PROCEDURE
WARNING - CAUTION
Never perform the following procedure when a bar is detected in the bar pusher
collet!
The replacement of the bar pusher, for a working cycle change or maintenance, may be
performed as follows:
- set the bar feeder to manual mode
, with close guide channels;
- press and hold
to start the automatic procedure, which allows the bar feeder to move
to the appropriate condition for the bar pusher replacement.
- In particular, by pressing
, the bar pusher is positioned past the clamp device, the
guide channels open, the bar pusher moves to the completely backwards position and the
bar drop control devices are lifted allowing for the bar pusher removal.
INFORMATION
If during the above mentioned operations
is released, the procedure will
stop. By pressing the button again, the procedure will start from where it was
paused.
NEW BAR PUSHER INTRODUCTION
- To load a new bar pusher, position it on the bar drop control devices and press [pupa_boss
_accomp] until the relative LED turns on.
WARNING - CAUTION
Check if the bar pusher has been correctly introduced into the first feeding
carriage housing.
Summary of Contents for Master 80 UP HyperFlexible
Page 2: ......
Page 4: ......
Page 10: ......
Page 16: ......
Page 25: ...2 TECHNICAL INFORMATION Master 80 UP HyperFlexible EN 2 Pag 9 9 ...
Page 36: ...EN 2 TECHNICAL INFORMATION Master 80 UP HyperFlexible 2 Pag 20 20 2 6 TECHNICAL DATA ...
Page 44: ......
Page 58: ......
Page 102: ......
Page 106: ...EN 6 USE AND OPERATION Master 80 UP HyperFlexible 6 Pag 4 4 ...
Page 134: ...EN 8 TROUBLES CAUSES SOLUTIONS Master 80 UP HyperFlexible 8 Pag 2 2 ...
Page 142: ......
Page 174: ...EN 11 COLLETS Master 80 UP HyperFlexible 11 Pag 24 24 ...