8
Zolar
Configuration
Examples
Ex.
Weep #1 Output
Aux. #1 Output
Sensor #1
Sensor #2
Notes:
1 Single-Temp
Weep
----
Temperature
----
Configure Aux #1 for control by Temperature.
2
Single-Temp Weep
Slab Heat
Temperature
Temperature
Configure Aux #1 for control by Temperature.
3
Single-Temp Weep
Exterior Lights
Temperature
Light
Configure Aux #1 for control by Light.
4
Single-Temp Weep
Equipment-Timed
Temperature
----- ( Time )
Configure Aux #1 for control by Time.
5
Dual-Temp Weep
----
Temperature
Temperature
Configure Aux #1 for control by Time. (2)
6
Dual-Temp Weep
Equipment-Timed
Temperature
Temp (Time)
Configure Aux #1 for control by Time. (2)
8
-----
Slab Heat
-----
Temperature
Configure Aux #1 for control by Temperature.
9
-----
Exterior Lights
-----
Light
Configure Aux #1 for control by Light.
10
-----
Equipment-Timed
-----
----- ( Time )
Configure Aux #1 for control by Time.
Notes:
1. When the Expanded Output Option is installed, its respective outputs and sensors (Weep #2, Aux #2, Sensor #3, and Sensor #4 ) are configured
and behave identically as the corresponding outputs and sensors in the table above.
2. Zolar detects the Dual-Temp Weep configuration automatically when you install two Temperature Probes, but configure Aux #1 for control by Time
rather than by the attached sensor. Zolar then automatically assigns the purpose of the second Temperature Probe to that of Dual-Temp Weep.
3. Zolar automatically detects the presence or absence of a Temperature Probe. When a Temperature Probe is not installed for Sensor #1 or for
Sensor #2 (when configured for temperature) Zolar will disable the function of the corresponding Output so that it remains in the Off state.
Zolar Factory Default
Configuration
The following table specifies the Menu Configuration values when Zolar is shipped from the factory unless other choices are specifically requested. Additionally,
should there be a replacement of, or failure of, the EEPROM chip that holds these values, Zolar will automatically re-initialize the EEPROM to these values.
Temperature Format
°F
Auxiliary Temperature
34°F On Lo
Weep Alarm Low
0°F
Weep Start Temperature
34°F
Auxiliary Light Level
0.7%
Auxiliary Alarm Low
30°F
Weep Full On Temperature
15°F
Auxiliary Time On
6:00 AM
Auxiliary
Alarm
High
120°F
Foam Blower Temperature
34°F
Auxiliary Time Off
6:00 PM
Days Warm, Days Powered
0