28
IDS 805 Installer Manual 700-266-02H Issued September 2009
Table 9: Alarm Reporting Codes
Value
Description
Reported As
10
Burglary
1130
1
Perimeter
1131
2
Interior
1132
3
24 Hour (Safe)
1133
4
Entry/Exit
1134
5
Day/night
1135
6
Outdoor
1136
7
Tamper
1137
8
Near alarm
1138
EXAMPLE
Assuming for a given installation it is required to differentiate between entry/exit, interior and general
burglary zones, and assuming that zone 1 is a front door (Entry/Exit zone), zone 2 is an interior PIR
(Interior zone) and zone 3 is a general burglary zone.
Program the following locations
1.
Location 86 (Zone 1) = 4 (Code 1134 = ENTRY/EXIT)
2.
Location 88 (Zone 2) = 2 (Code 1132 = INTERIOR)
3.
Location 90 (Zone 3) = 10 (Code 1130 = BURGLARY)
NOTES ON DOMESTIC REPORTING:
If dual reporting is enabled then domestic reporting will dial both phone numbers as programmed into
locations 48-63 and 64-79. The data to be reported will be transmitted 3 times immediately after the
phone number is dialled. This format provides for a simple form of easily identifiable remote alarm which
may be reported to an office, mobile phone etc.
When using Domestic Reporting the number will be dialled and the data will be transmitted the number of
times as programmed into the number of dial attempts (location 151).
NOTES ON PROGRAMMING TELEPHONE NUMBERS:
To dial a "0" program a [10] into the location.
To dial a "*" program an [11] into the location.
To dial a "#" program a [12] into the location.
To create a 12 second pause in the number program a [14] into the location.
To create a 4 second pause in the number program a [15] into the location.
To terminate a telephone number, program a [0] (not 10) into the location immediately following
the last digit of the telephone number.
LOCATIONS 48-63
Primary Telephone Number
Loc. No.
48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63
These locations contain the primary telephone number, which may be up to sixteen digits long. A four-
second delay can be programmed at any point by entering a value of
[15]
in the respective location.
Summary of Contents for 805
Page 1: ...1 IDS 805 Installer Manual 700 266 02H Issued September 2009...
Page 2: ...2 IDS 805 Installer Manual 700 266 02H Issued September 2009...
Page 5: ...5 IDS 805 Installer Manual 700 266 02H Issued September 2009...
Page 6: ...6 IDS 805 Installer Manual 700 266 02H Issued September 2009...
Page 48: ...48 IDS 805 Installer Manual 700 266 02H Issued September 2009...