32
IDS 805 Installer Manual 700-266-02H Issued September 2009
be appended to this reporting code to provide the 2 digit reporting code.
LOCATION 118
Tamper Zone Reporting Code
The zone tamper code will only be reported if the zone tamper function has been enabled, see location
11. The zone number will be appended to this reporting code to provide the 2 digit reporting code.
LOCATION 119
Zone Shutdown Reporting Code
The zone shutdown code will be reported if the system is armed and a zone is automatically bypassed as
a result of multiple violations of that zone while the panel is armed. The number of permissible violations
is dependent on the value programmed into location 140. The zone number will be appended to this
reporting code to provide the 2
nd
digit of the reporting code.
LOCATION 120
Cancel Reporting Code
If the siren is sounding and the siren is cancelled by either a valid user code or key/remote, a cancel
code will be reported. A silent alarm or silent panic will not cause the cancel code to be reported. The
user number will be appended to this reporting code to provide the 2
nd
digit of the reporting code.
LOCATION 121
Zone Restoral Reporting Code
If the panel is armed and a violation of a zone occurs followed by the zone returning to the normal (non-
alarm) state, a zone violation followed by a zone restoral will be reported. The zone restoral code
indicates that the zone has returned to the ready condition. The zone number will be appended to this
reporting code to provide the 2
nd
digit of the reporting code.
LOCATIONS 122-123
Download Complete Reporting Code
This code will be sent once a successful download to a panel has been completed.
LOCATIONS 124-125
TLM Fail Reporting Code
This code will be sent if telephone line monitoring is enabled and the line voltage drops below 9V for
more than 30-60 seconds. A failure condition will be logged in the event log and if armed in the away
mode the siren will sound.
NOTE:
A TLM failure indicates that the telephone line is either not functional or not present. This reporting code
should only be used in conjunction with a radio linked to the dialler.
LOCATIONS 126-127
TLM Restore Reporting Code
This code will be sent once telephone line monitoring has been restored.
LOCATIONS 128-129
Low Battery Reporting Code
The low battery condition will be reported if the battery voltage drops below 10 volts. If the battery fuse
blows then the battery will discharge and a low battery condition will be reported, even if the AC power is
present.
LOCATIONS 130-131
Low Battery Restoral Reporting Code
This code will be sent once the battery voltage has been restored. The battery voltage has to rise to
Summary of Contents for 805
Page 1: ...1 IDS 805 Installer Manual 700 266 02H Issued September 2009...
Page 2: ...2 IDS 805 Installer Manual 700 266 02H Issued September 2009...
Page 5: ...5 IDS 805 Installer Manual 700 266 02H Issued September 2009...
Page 6: ...6 IDS 805 Installer Manual 700 266 02H Issued September 2009...
Page 48: ...48 IDS 805 Installer Manual 700 266 02H Issued September 2009...