background image

Printed in China 

2015 V 1.0

Wireless Keypad 

User Manual

SOS

Summary of Contents for KP-AI

Page 1: ...Printed in China 2015 V 1 0 Wireless Keypad User Manual SOS ...

Page 2: ...arts List Working Status of Keypad Installations Digital Keypad Operation Disarm by RFID Tag Card Settings Enroll the Keypad to the Control Panel Connecting Electronic Door Lock Add Delete RFID Tag Card Restore System to Default Settings Specification Maintenance Frequently Asked Question ...

Page 3: ...open the door at the same time very convenient and suitable for both homes and offices Parts List 1 x User Manual RFID tags 1 x Wired Cables AAA AAA AAA 3 x 1 5V AAA LR03 Battery 4 x Screws with plastic plugs Wireless keypad Working Status of Keypad Green LED Blue LED Red LED Arm Stay Arm Disarm SOS Key Wake Up Key RFID Reader RFID Tags Up to50 pcs can be expanded RFID tags 3 2 SOS Green LED Normal ...

Page 4: ...nd Negative Terminals for Battery Battery Slot Wired Cables Interface Tamper Switch A A A 5 4 1 Open the keypad case fix the rear cover at the suitable mounting location please make sure the location level and fix the rear cover in position on the wall by screws 2 Fasten the front cover of keypad on the rear cover 3 Screw the bottom on 3 1 2 ...

Page 5: ... If connected Mute Mode Press button then press or within 3 seconds to enter arming or disarming state in mute mode SOS Emergency Call If there s an emergency situation press SOS for 3 seconds to activate an immediate alarm Note To avoid any false operation please enable Emergency Call with Password refer to Page9 Disarm by RFID Tag Card 7 6 Note Press to activate keypad if no operations are perfo...

Page 6: ...triggering SOS button Press SOS button for 3 seconds without password Normal Working Mode On If keypad is powered by DC 12V power normal working mode is recommended The green LED keeps on And digital keypad can be operated without pressing activate key In normal mode user can disarm the systemwith RFID cards close to the reader directly Default Default Default Default When quick arm function is en...

Page 7: ...d 2 beeps will be heard when system disarms 2 beeps will be heard when system disarms Factory Default Normal Working Mode Off If keypad is powered by the batteries power saving mode is recommended Keypad should be activated by pressing activate key before operating Ifno operationwithin 5 seconds system enters power saving mode Default Default Enroll the keypad to the control panel Press enroll butt...

Page 8: ...ress to activate keypad then enter admin password 0 red LED lights up put RFID tag close to the RFID reader the RFID tag is deleted after blue LED flashes once and one beep is heard Note Multiple RFID tags can be continuously deleted within 30 seconds Clearing All RFID Tags Press to activate keypad then enter admin password 0 red LED light up Press and hold 0 button up to 3 seconds all RFID tags ar...

Page 9: ...use 2 The power supply of keypad should be checked as often as necessary to avoid any loss in transmission distance caused by low battery 3 Check the keypad regularly to ensure the system works properly in case of emergency 4 Please install the keypad in cool dry shaded location 5 Do not install the keypad near any heat source eg above a radiator 6 ThekeypadismadeofABS Pleasekeepitawayfromstrongli...

Page 10: ...are interfering with the signal C The optimal distance between the keypad control panel is 80 meters in open area Check that your keypad is within this distance A Check if the RFID tags were enrolled to the keypad Please refer to Page 12 for operation guide B Check the LED indication and see if system is in power saving mode Before using the RFID tags to disarm the system please press to activate ...

Reviews: