59
⑤
Please refer as below for other values.
Reserved:
Not used
Warming Up Display:
If you use SMART-30 R, LED buttons are blinked during print head is
warming up. You can adjust the timing of LED blinking by adjusting values of “Warming Up
Display”. It becomes faster as the value is smaller.
Mag. Write Mode:
You can order the way how to encode magnetic stripe.
“L:A, H:I”: encodes 3 tracks at once for LoCo card and encodes at twice by dividing 1,3 and 2
track for HiCo cards.
Magnetic Space:
The distance of magnetic stripe when you encode.
SBS Only:
Please enable it when you issue cards with software programed by SDK. This option
disables printer device driver.
Board Type:
to choose they type of mainboard. Please do not change it.
Security:
There are several ways to set a security function for SMART-50.
PC Authentication:
You can use a printer with specific PC. It is activated when you click “Set
PC Serial”.
Physical Key:
You can set this option when physical key is installed.
User/Root Authentication
: You can set passwords for User and Administrator.
Use USB Serial:
When SMART-50 is connected to USB, it transmits the USB serial number to
PC. Default is the same number used by all SMART-50. Please set this option when you use
multiple SMART-50 printers connected to 1 PC via USB. It enables unique serial numbers for
each USB.
Ribbon Position:
To set the ribbon position on card. Please set it default.
Warming Up Temp.:
To control the temperature of warming up before printing. For SMART-30
R, you need to warm up print head to print high quality. We recommend warming up to 50
degrees.
Card Out Delay:
To set timing of hopper motor for ejecting card. Please set it default.
Card Out:
to set the way to eject cards.
Error Card Out:
to set the way to eject error cards.
DCL Mode:
When you use SDK and print cards with DCL mode, you don’t need to install printer
device driver.
Dump Mode:
It records log data.