6. Programming the UVR 61-3 HEP
Installation instructions Hygienik 2.0
36
Programming the UVR 61-3 HEP
C
h
a
p
te
r 06
Change
Min
limitation switch-off threshold for sensor
T3
(not assigned), factory
setting
42
°C,
as follows: Press , display begins to
fl
ash
Change setting with or
Save setting with , display stops
fl
ashing
Press
►
Change
Diff
erential switch-on threshold for sensor
T1
(collector sensor), factory
setting
8.0
K
as follows: Press , display begins to
fl
ash
Change setting with or
Save setting with , display stops
fl
ashing
Press
►
Change
Diff
erential switch-off threshold for sensor
T1
(collector sensor), factory
setting
4.0
K
as follows: Press , display begins to
fl
ash
Change setting with or
Save setting with , display stops
fl
ashing
Press
►
Change
Diff
erential switch-on threshold for circulation pump (not used),
factory setting
8.0
K,
as follows: Press , display begins to
fl
ash
Change setting with or
Save setting with , display stops
fl
ashing
Press
►
Change
Diff
erential switch-off threshold for circulation pump (not used),
factory setting
4.0
K,
as follows: Press , display begins to
fl
ash
Change setting with or
Save setting with , display stops
fl
ashing
Press
►
Change display of time, e.g.
16.24
as follows: Press , minute display begins to
fl
ash
Change setting with or ,
Press , hour display begins to
fl
ash
Save setting with , display stops
fl
ashing
Press
►
Par
K
min
2
8.0
Par
K
1
4.0
Par
K
1
8.0
Par
K
2
4.0
Par
K
2
16.24
Par
K
42