(C) IDM ENERGIESYSTEME GMBH
4. Installation
Installation instructions Hygienik 2.0
20
Installation
Ins
tall
a
tio
n
When the sensors have been correctly positioned,
the insulation jacket can be installed. The insulation
sections are pulled over the connections with the
Neopor/
fl
eece insulation facing inward. The sensor
cables are routed out of the insulation on the side at
the top.
The hook fastening strip is hooked into the
fi
rst catch
and closed on the opposite side from bottom to top.
The insulation jacket is tightened using the hook
strips until it lies snugly against the tank body. When
the insulation is lying
fi
rmly against the tank body,
fi
t
the cover strip provided onto the fastening strip.
Store the insulation jacket in a warm
room prior to installation, or wait until the
tank has heated before closing the hook
fastening strip!
Pull the insulation jacket on carefully to
avoid damaging it!
2 persons are required to install the insu-
lation jacket with hook fastening strip!
Cover strip