(C) IDM ENERGIESYSTEME GMBH
12. Technical documentation
Installation instructions AERO SLM
48
technical documentation
Ka
p
ite
l 1
2
12. Technical documentation
TECHNICAL
DOCUMENTATION
Rev.0/01-12-2016
TECHNICAL
DOCUMENTATION
according Directive 2010/30/EU and corresponding Regulation (EU) No. 811/2013 (Energy Labelling),
Dircetive 2009/125/EC and corresponding Regulation (EU) No. 813/2013 (Ecodesign)
Model:
AERO
SLM
3-
11
Model:
Type of heat pump:
Low-temperature heat pump: (Yes/No)
Temperature application: (35°C/55°C)
Equipped with supplementary heater: (Yes/No)
Heat pump combination heater: (Yes/No)
Yes
AERO
SLM
3-11
Air-to-water heat pump
No
high temperature (55°C)
Yes
cold
average
warm
cold
average
warm
Rated heat output
P
rated
8,9
8,1
9,9
kW
Seasonal space heating efficiency
Ș
s
120
135
175
%
Outdoor temperature T
j
Outdoor temperature Tj
Climate condition
Climate condition
Declared capacity for part load
(indoor tem
p
erature = 20 °C
)
Declared capacity for part load
(indoor tem
p
erature = 20 °C
)
T
j
= – 15 °C
P
dh
7,2
-
-
kW
T
j
= – 15 °C
COP
d
1,95
-
-
---
T
j
= – 7 °C
P
dh
5,5
7,5
-
kW
T
j
= – 7 °C
COP
d
2,68
2,30
-
---
T
j
= +2 °C
P
dh
3,3
4,4
9,9
kW
T
j
= +2 °C
COP
d
3,70
3,58
2,36
---
T
j
= +7 °C
P
dh
3,1
3,0
6,4
kW
T
j
= +7 °C
COP
d
4,93
3,00
3,93
---
T
j
= +12 °C
P
dh
3,4
3,4
3,2
kW
T
j
= +12 °C
COP
d
6,03
3,39
3,19
---
T
j
= Bivalenz temperature (T
biv
)
P
dh
7,2
8,5
9,9
kW
T
j
= Bivalenz temperature (T
biv
)
COP
d
1,95
2,02
2,36
---
(indoor
temperature
20
C)
(indoor
temperature
20
C
)
T
j
= Operation limit temperature (TOL)
P
dh
6,9
8,5
9,9
kW
T
j
= Operation limit temperature (TOL)
COP
d
1,82
2,02
2,36
---
Bivalenz temperature (Tbiv)
T
biv
-15,0
-10,0
2,0
°C
Operation limit temperature
TOL
-18,0
-10,0
2,0
°C
Cycling interval capacity for heating
P
cych
kW
Cycling interval capacity for heating
COP
cyc
---
Degradation co-efficient
C
dh
0,9
0,9
0,9
---
Heating water operating limit temperature
WTOL
62
62
62
°C
Power consumption in modes other than active mode
Supplementary heater
Thermostat-off mode
P
TO
0,026
0,026
0,026
kW
Rated heat output (*)
P
sup
1-6
1-6
1-6
kW
Standby
m
ode
P
SB
00
26
0
026
0
026
kW
Standby
m
ode
P
SB
0,
026
0,
026
0,
026
kW
Off-mode
P
OFF
0,026
0,026
0,026
kW
Type of energy input
Crankase heater mode
P
CK
00
0
kW
Other items
For air-to-water heat pumps:
Capacity control
Rated air flow rate, outdoors
---
3.600
3.600
3.600
m
3
/h
Sound power levels, indoors/outdoors
L
WA
45 / 50
45 / 50
45 / 50
dB
For water- or brine-to-water heat pumps:
Annual energy consumption
Q
HE
7.104
4.887
3.108
kWh
Rated brine or water flow rate, outdoor heat exchanger
---
n.a.
n.a.
n.a.
m
3
/h
electrical
variable
For heat pump combination heater:
Declared load profile
Water heating energy efficiency
Ș
wh
%
Daily electricity consumption
Q
elec
kWh
Daily fuel consumption
Q
fuel
n.a.
n.a.
n.a.
kWh
Annual electricity consumption
AEC
kWh
Annual fuel consumption
AFC
n.a.
n.a.
n.a.
GJ
Contact details:
IDM-Energiesysteme, Seblas 16-18, 9971 Matrei i.O., Austria
n.a.
100
n.a.
n.a.
Rev.0/01-12-2016