(C) IDM ENERGIESYSTEME GMBH
3. Description
Installation instructions AERO SLM
12
description
Mo
n
ta
g
e H
e
izungsseitig
Heat pump type
AERO SLM 3-11
AERO SLM 6-17
Model
without HGL
HGL
without HGL 230 V
without HGL
HGL
Space heating water energy e
ffi
ciency class
35°C 55°C
35°C 55°C
Unit
Performance data acc. to EN 14511 at nominal speed
Heat output at A2°C/W35°C
kW
5.92
11.25
Power consumption at A2°C/W35°C
kW
1.35
2.50
COP at A2°C/W35°C
-
4.37
4.50
Cooling capacity at A35°C/W18°C
kW
7.80
11.98
Power consumption at A35°C/W18°C
kW
1.81
2.70
EER at A35°C/W18°C
-
4.32
4.43
Sound emission acc. to EN 12102
1
Sound power level nominal indoor unit
dB(A)
45
45
Sound power level maximum indoor unit
dB(A)
48
55
Sound power level nominal outdoor unit
dB(A)
50
57
Sound power level maximum outdoor unit
dB(A)
53
62
Sound reduced operation outdoor unit (reduced power)
dB(A)
49
57
The sound pressure level can be calculated
with the iDM-sound calculation tool
Dimensions indoor unit
Height / Width / Depth
mm
1262/ 620 / 762
Weight
kg
165
168
Minimum size of installation room
2
(with standard
fi
lling)
m³
9.32
10.90
Dimensions outdoor unit
Height / Width / Depth
mm
1180 / 1110 / 745
1546 / 1090 / 745
Weight
kg
113
150
3.9. Technical data
A
+++
A
+++
A
+++
A
++