(C) IDM Energiesysteme GmbH
5. General description
Installation instructions AERO ILM
30
192558/192559
192551/192552
193805
192555
192501/192531
192521
193809
Installation
5.10. Installation with a straight air duct
This variant is similar to the corner installation and can be used if the direct corner installation without channels
from on-site conditions can not be implemented.
192521 ... Wall connection intake for airtight changeover
192501 ... Weather-shield grilles inlet
192531 ... Mesh grilles inlet (12 mm)
193805 ... outlet panels for air duct
192551 ... air duct outlet isolated 1.0 m
192552 ... air duct outlet isolated 1.5 m
193809 ... cover for wall breakthrough for air duct
192555 ... air duct wall connection, isolated
192558 ... Weather-shield grilles outlet via air duct
192559 ... Mesh grilles outlet via air air duct (12 mm)
The air ducts can be connected to the left or to the right side of the heat pump. In consequence
this means that heating connections and electrical connections can be either on the left-hand side
or on the right-hand side.
When air is conducted via a light shade, it must be at least the same width as the wall opening.
The depth must be at least 400 mm.