@GST / @SST
Saturation
Getting
Command
@GST
Response
@GST, saturation_1, saturation_2, saturation_3, saturation_4,
・・・
, saturation_8
Setting
Command
@SST, ch_1, saturation_1 (, ch_2, saturation_2
・・・
)
Response
@SST, ch_1, saturation_1 (, ch_2, saturation_2
・・・
)
Parameter
saturation_1-8: Input saturation
0 to 200 [Default] 100
ch_1-8: Input channel
0 = All inputs, 1 = IN1 to 8 = IN8
Getting
example
Command
Response
@GST
@GST,100,100,100,100,105,100,100,100
Description Getting the set saturations.
IN5: 105 %, other inputs: 100 %
Setting
example
Command
Response
@SST,5,105
@SST,5,105
Description Setting IN5 saturation to 105%.
Remarks
Hue can be set up to 200%. However, if the dot clock of the input signal exceeds
170 MHz, 100% is applied regardless of this setting.
@GSU / @SSU
Black level
Getting
Command
@GSU
Response
@GSU, setup_1, setup_2, setup_3, setup_4,
・・・
, setup_8
Setting
Command
@SSU, ch_1, setup_1 (, ch_2, setup_2
・・・
)
Response
@SSU, ch_1, setup_1 (, ch_2, setup_2
・・・
)
Parameter
setup_1-8: Input black level
-20 = -20 × 0.5 (-10.0 %) to +20 = +20 × 0.5 (+10.0 %)
[Default]
±
0 =
±
0.0 %
ch_1-8: Input channel
0 = All inputs, 1 = IN1 to 8 = IN8
Getting
example
Command
Response
@GSU
@GSU,0,0,0,0,15,0,0,0
Description Getting the input black level.
IN5: +7.5%, other inputs: 0%.
Setting
example
Command
Response
@SSU,5,15
@SSU,5,15
Description Setting the IN5 black level to +7.5%.
Remarks
-