Part 3 - Remote Setup
34
Alarm Out
DC-B1103 / DC-B1203 only
Select
Alarm Out
to enable alarm out.
•
Dwell Time
: Designate the alarm out duration.
When an event occurs, alarm out will be generated
for the specified duration.
•
Schedule
: Specify the alarm out schedule. Alarm
out is generated during the specified period only.
Select
to send out emails.
•
SMTP Server/Port
: Enter the SMTP server's IP
address (or domain name) and port number you
received from the network administrator.
If a DNS server has been set up during network
configuration, you can enter a domain name instead
of an IP address. If using an SMTP server requiring
an SSL connection, select the
Use SSL/TLS
option.
•
Authentication
: Enter a user ID and password if
user authentication is required by the SMTP server.
•
Sender/Recipient(s)
: Enter the sender and
recipients' addresses. (Up to 10) The addresses
must be properly formatted and include the @
symbol.
Remote Callback
Select
Remote Callback
to send callback messages
to a remote system.
•
Not supported from the IDIS Web program.
•
The camera must be registered to the remote
system in order to use the
Remote Callback
feature.
•
IP Address
: Enter the IP address and port number
of the remote system that will receive the messages.
•
Retry
: Designate how many reattempts to make if
message delivery fails.