0901082 Rev: D (08/08)
Page 4 of 12
INTRODUCTION
Ultra Micro-Pro UMP-Series warewash systems provide the versatility of probe or probeless detergent control through
advanced microprocessor design. With the capability of controlling up to two products, and the choice of liquid or dry
detergent, virtually any warewash application can be accommodated.
The UMP Series warewash control features simplicity and versatility.
SLIDE SWITCH SETTINGS
•
Probe/Probeless Switch: Allows you to select
operation with or without a probe
•
Door/Conveyor Switch: Sets alarm delay range for
probe mode. Sets initial charge timing range for
probeless mode.
•
Low/High Range Switch: Used if operating in probe
mode. Selects concentration ranges.
•
Low/High Audio Switch: Sets the alarm volume.
•
On/Off Rinse Limit Switch: When on, stops the rinse
pump after 30 seconds.
POTENTIOMETER SETTINGS
•
Concentration or Recharge Pot: In “probe mode” sets
detergent concentration strength. In “probeless mode”
sets the pump time necessary to recharge the
detergent concentration.
•
Alarm Delay or Initial Charge Pot: In “probe mode”
sets the time before the alarm sounds if the probe
senses low detergent concentration. In “probeless
mode” sets the pump time necessary to initially
charge the detergent concentration.
•
Rinse Speed Pot: Adjust the speed at which the rinse
pump runs.
•
Rinse Delay Pot: Delays the rinse pump from
0 to 14 seconds.
CONCENTRATION OR RECHARGE
ALARM DELAY OR INITIAL CHARGE
RINSE SPEED
RINSE DELAY