SE2L User’s Manual (SE9Z-B1865)
127
8.4 Periodical inspection
Periodical inspection should be performed to ensure the detection capability of SE2L. Table 8-4 below
shows an example of periodical inspection items. It is recommended to perform this inspection at every six
months interval. This inspection should be performed together with the daily inspection.
Table 8-4 Periodical inspection list example
Condition
No.
Check item
Yes No
Remark
1
Screws are tightly fastened
2
No displacement from the original mounting position
3
No scratch or crack on the optical window
4
Screws of the optical window are tightly fastened
5
No oil, grease or dirt on the optical window
6
No visible damage on SE2L
7
Cable connector is in good condition and tightly fastened
8
Area is switched and correctly displayed on SE2L when
the input signals are changed according to the area
switching table
9
The OSSD signal switches from ON state to OFF state
when the test piece is placed inside the protection zone
10
The OSSD signal remains in OFF state when the test piece
is moved inside the protection zone
11
The OSSD signal switches from OFF state to ON state
when the test piece is removed from the protection zone
12
If the SE2L is in automatic restart mode, OSSD signal
switches from ON-state to OFF-state when the test piece is
placed inside the protection zone and switches from
OFF-state to ON-state when the test piece is removed
13
If SE2L is in manual restart mode, OSSD signal switches
from ON-state to OFF-state when the test piece is placed
inside the protection zone and remains in OFF-state when
the test piece is removed
14
If the start interlock function is configured, starting the
SE2L without placing the test piece in protection zone
causes the OSSD signal to remain in OFF-state until the
RESET signal is provided
15
If the muting function is configured, SE2L terminates the
muting (OSSD switches to OFF-state) when the test piece
is placed inside the protection zone other than the muting
area even though the muting conditions are fulfilled.
16
If the muting function is configured, SE2L does not switch
to mute state when the muting input sequence is different
than the specified sequence
17
If the muting function is configured, SE2L does not switch
to mute
state when the time interval between two muting
inputs exceeded the specified time interval
Summary of Contents for SE2L Series
Page 1: ...SE9Z B1865 SE2L Series Safety Laser Scanner User s Manual ...
Page 100: ...SE2L User s Manual SE9Z B1865 99 Figure 7 31 b Function Figure7 31 c Area ...
Page 143: ...SE2L User s Manual SE9Z B1865 142 13 External dimension 13 1 SE2L H05LP mm ...
Page 144: ...SE2L User s Manual SE9Z B1865 143 13 2 SE2L H05LPC mm ...
Page 145: ...SE2L User s Manual SE9Z B1865 144 13 3 Base mounting bracket mm ...
Page 146: ...SE2L User s Manual SE9Z B1865 145 13 4 Rear mounting bracket mm ...
Page 147: ...SE2L User s Manual SE9Z B1865 146 13 5 Simple base mounting bracket mm ...
Page 149: ...SE2L User s Manual SE9Z B1865 148 13 7 Simple rear mounting bracket Long type mm ...
Page 150: ...SE2L User s Manual SE9Z B1865 149 13 8 Cover Protection Bracket mm ...