SE2L User’s Manual (SE9Z-B1865)
35
3.9.3 Muting override function
Muting override is a function to recover SE2L when the OSSD is switched to OFF state due to muting
related errors by temporarily suspending the safety function. Override function is active when the override
input (OVERRIDE 1/2) and the reset input (RESET 1/2) are switched in a sequence. Figure 3-21 shows the
override sequence.
Override start conditions
▶
At least
one of the muting inputs is in ON-state.
▶
Object is present in the protection zone.
▶
Time interval between override input and reset input is within 0.03s to 1s (T3).
Override stop conditions
▶
Both muting inputs are in OFF-state.
▶
Override input or reset input is in OFF-state.
▶
When predefined maximum override time T4 exceeds.
▶
Error is detected by self-diagnostic function of the SE2L.
▶
During override state when area is switched to the other area.
Maximum override period (T4)
Maximum override period can be selected from one of these values
▶
1 minute
▶
6 minutes
▶
12 minutes
Figure 3-21 Override Sequence
Summary of Contents for SE2L Series
Page 1: ...SE9Z B1865 SE2L Series Safety Laser Scanner User s Manual ...
Page 100: ...SE2L User s Manual SE9Z B1865 99 Figure 7 31 b Function Figure7 31 c Area ...
Page 143: ...SE2L User s Manual SE9Z B1865 142 13 External dimension 13 1 SE2L H05LP mm ...
Page 144: ...SE2L User s Manual SE9Z B1865 143 13 2 SE2L H05LPC mm ...
Page 145: ...SE2L User s Manual SE9Z B1865 144 13 3 Base mounting bracket mm ...
Page 146: ...SE2L User s Manual SE9Z B1865 145 13 4 Rear mounting bracket mm ...
Page 147: ...SE2L User s Manual SE9Z B1865 146 13 5 Simple base mounting bracket mm ...
Page 149: ...SE2L User s Manual SE9Z B1865 148 13 7 Simple rear mounting bracket Long type mm ...
Page 150: ...SE2L User s Manual SE9Z B1865 149 13 8 Cover Protection Bracket mm ...