SE2L User’s Manual (SE9Z-B1865)
30
3.7.3.1 Automatic restart
SE2L will restart automatically when interlock function is disabled or only the start interlock function is
enabled. When obstacle from the protection zone is removed, OSSD signals switch from OFF-state to
ON-state automatically. OSSD response times for ON and OFF states are configurable (See section 3.12).
However, if SE2L is in the lockout state due to error,
OSSDs will remain in OFF-state even if the interlock
function is disabled.
Figure 3-15 Timing chart of automatic restart
In automatic restart configuration OSSD will automatically switch to ON state after
the object is removed. Confirm the safety while removing the object.
Configured response time should be sufficient for the machine or AGV to stop safely.
Summary of Contents for SE2L Series
Page 1: ...SE9Z B1865 SE2L Series Safety Laser Scanner User s Manual ...
Page 100: ...SE2L User s Manual SE9Z B1865 99 Figure 7 31 b Function Figure7 31 c Area ...
Page 143: ...SE2L User s Manual SE9Z B1865 142 13 External dimension 13 1 SE2L H05LP mm ...
Page 144: ...SE2L User s Manual SE9Z B1865 143 13 2 SE2L H05LPC mm ...
Page 145: ...SE2L User s Manual SE9Z B1865 144 13 3 Base mounting bracket mm ...
Page 146: ...SE2L User s Manual SE9Z B1865 145 13 4 Rear mounting bracket mm ...
Page 147: ...SE2L User s Manual SE9Z B1865 146 13 5 Simple base mounting bracket mm ...
Page 149: ...SE2L User s Manual SE9Z B1865 148 13 7 Simple rear mounting bracket Long type mm ...
Page 150: ...SE2L User s Manual SE9Z B1865 149 13 8 Cover Protection Bracket mm ...