Switches &
Pilot Lights
Display
Lights
Display
Units
LED
Illumination
Units
Safety
Products
Terminal
Blocks
Comm.
Terminals
AS-Interface
Relays &
Timers
Sockets
Circuit
Protectors
Power
Supplies
PLCs &
SmartRelay
Operator
Interfaces
Sensors
Control
Stations
Explosion
Protection
References
Flush
Silhouette
717
HS5E Miniature Interlock Switches with Solenoid
When the door hinge is on the extension line of the actuator
•
mounting surface:
(47)
(231)
I
nterlock Switch
Mounting Holes
260mm
Minimum Radius
Door Hinge
(48.2)
Door Hinge
Minimum
Radius
Centers 12 mm: 230 mm
Centers 20 mm: 310 mm
Actuator Angle Adjustment
Using the angle adjustment screw, the actuator angle can be
•
adjusted (refer to the dimensional drawing on page 709).
Adjustable angle: 0 to 20°
The larger the adjusted angle of the actuator, the smaller the
•
applicable radius of the door opening.
After installing the actuator, open the door. Then adjust the
•
actuator so that its edge can be inserted properly into the
actuator entry slot of the interlock switch.
After adjusting the actuator angle, apply Loctite to the
•
adjustment screw so that the screw will not move.
When using the HS9Z-A53 Angle Adjustable
(vertical) Actuator
When the door hinge is on the extension line of the interlock
•
switch surface: 50 mm
When the door hinge is on the extension line of the actuator
•
mounting surface: 80 mm
Inter
loc
k Switch
Mounting Hole
Door
Hinge
Minim
um Radius
50 mm
Door Hinge
Inter
loc
k Switch
Mounting Hole
M
inim
um Rad
ius
80 mm
(36.2)
(38)
(68)
(56.5)
When using the HS9Z-A55 Angle Adjustable
(vertical/horizontal) Actuator
When the door hinge is on the extension line of the interlock
•
switch surface: 50 mm
(58)
(55.5)
(36.2)
Door Hinge
Door
Hinge
50 mm
Minim
um Radius
70 mm
Vertical Swing
Horizontal Swing
Vertical Swing
Horizontal Swing
(55.5)
Minim
um Radius
70 mm
(38)
Inter
loc
k Switch
Mounting Hole
Inter
loc
k Switch
Mounting Hole
(36.2)
Minim
um Radius
50 mm
Door
Hinge
Door Hinge
Minim
um Radius
When the door hinge is on the extension line of the actuator
•
mounting surface: 70 mm
Mounting Examples
HS9Z-A51
Actuator
Door
HS5E
Interlock
Switch
Door Stop
Application on Sliding Doors
Latch
Application of Hinged Doors
HS5E
I
nterlock Switch
HS9Z-A52 Actuator
HS9Z-SH5
Sliding Actuator
Door
Installing the Head
Do not use the plastic and metal head of he HS5B interlock
switches on the HS5E. The metal heads of the HS5E and
HS5B interlock switches look similar. When using these
interlock switches adjacently, ensure that the heads are not
interchanged.
black
∗
Plastic
(black
or gray)
HS5
E
HS5B
Metal Head
Metal Head
Plastic Head
Metal
(silver color)
(gray)
∗
The HS5E metal head can be distinguished easily with the black
plastic part (HS5E metal head has gray plastic part).
Rotating the Head
The head of the HS5E can be rotated by removing the four
screws from the corners of the HS5E head and reinstalling
the head in the desired orientation. Before wiring the HS5E,
replace the head if necessary. Before replacing the head, turn
the manual unlock to the UNLOCK position using the manual
unlock key. When reinstalling the head, make sure that no
foreign object enters the interlock switch. Tighten the screws
tightly, without leaving space between the head and body,
otherwise the interlock switch may malfunction.
Recommended tightening torque: 0.9 to 1.1 N·m.
Head can be rotated.
Factory Setting
Instructions
HS5E