HS5E Miniature Interlock Switches with Solenoid
Standard
Lock Mechanism
Circuit Code
Contact Confi guration
Indicator
Cable
Length
Part No.
Solenoid Lock
A
Main Circuit: 1NC+1NC, Door Monitor Circuit: 1NO,
Lock Monitor Circuit: 1NO
Without
1m
HS5E-A7Y001
3m
HS5E-A7Y003
5m
HS5E-A7Y005
With
1m
HS5E-A7Y401-G
3m
HS5E-A7Y403-G
5m
HS5E-A7Y405-G
B
Main Circuit: 1NC+1NC, Door Monitor Circuit: 1NO,
Lock Monitor Circuit: 1NC
Without
1m
HS5E-B7Y001
3m
HS5E-B7Y003
5m
HS5E-B7Y005
With
1m
HS5E-B7Y401-G
3m
HS5E-B7Y403-G
5m
HS5E-B7Y405-G
C
Main Circuit: 1NC+1NC, Door Monitor Circuit: 1NC,
Lock Monitor Circuit: 1NO
Without
1m
HS5E-C7Y001
3m
HS5E-C7Y003
5m
HS5E-C7Y005
With
1m
HS5E-C7Y401-G
3m
HS5E-C7Y403-G
5m
HS5E-C7Y405-G
D
Main Circuit: 1NC+1NC, Door Monitor Circuit: 1NC,
Lock Monitor Circuit: 1NC
Without
1m
HS5E-D7Y001
3m
HS5E-D7Y003
5m
HS5E-D7Y005
With
1m
HS5E-D7Y401-G
3m
HS5E-D7Y403-G
5m
HS5E-D7Y405-G
F
Main Circuit: 1NC+1NC, Door Monitor Circuit: 2NC
Without
1m
HS5E-F7Y001
3m
HS5E-F7Y003
5m
HS5E-F7Y005
With
1m
HS5E-F7Y401-G
3m
HS5E-F7Y403-G
5m
HS5E-F7Y405-G
G
Main Circuit: 1NC+1NC, Door Monitor Circuit: 1NC, 1NO
Without
1m
HS5E-G7Y001
3m
HS5E-G7Y003
5m
HS5E-G7Y005
With
1m
HS5E-G7Y401-G
3m
HS5E-G7Y403-G
5m
HS5E-G7Y405-G
H
Main Circuit: 1NC+1NC, Lock Monitor Circuit: 2NC
Without
1m
HS5E-H7Y001
3m
HS5E-H7Y003
5m
HS5E-H7Y005
With
1m
HS5E-H7Y401-G
3m
HS5E-H7Y403-G
5m
HS5E-H7Y405-G
J
Main Circuit: 1NC+1NC, Lock Monitor Circuit: 1NC, 1NO
Without
1m
HS5E-J7Y001
3m
HS5E-J7Y003
5m
HS5E-J7Y005
With
1m
HS5E-J7Y401-G
3m
HS5E-J7Y403-G
5m
HS5E-J7Y405-G
The contact confi guration shows the status when the actuator is inserted and the switch is locked.
•
The contact confi guration shows the status when the indicator is installed.
•
Actuators are not supplied with the interlock switch and must be ordered separately.
•
A1
A2
(+)
(–)
Main Circuit:
24
11
23
12
42
41
54
53
Monitor Circuit:
Monitor Circuit:
Door Monitor
(Actuator inserted)
Lock Monitor
(Solenoid ON)
51
52
41
42
12
23
11
24
Main Circuit:
Monitor Circuit:
Monitor Circuit:
22
11
21
12
41
53
54
42
Main Circuit:
Monitor Circuit:
Monitor Circuit:
Monitor Circuit:
Monitor Circuit:
41
12
11
21
22
51
Main Circuit:
52
42
11
12
42
41
21
22
32
31
Main Circuit:
Monitor Circuit:
Monitor Circuit:
41
42
12
11
21
22
33
34
Main Circuit:
Monitor Circuit:
Monitor Circuit:
11
12
42
41
61
62
51
52
Main Circuit:
Monitor Circuit:
Monitor Circuit:
41
42
12
11
51
52
63
64
Main Circuit:
Monitor Circuit:
Monitor Circuit:
HS5E