HS5E Miniature Interlock Switches with Solenoid
Four-circuit Independent Output - Spring Lock
Interlock Switch Status
Status 1
Status 2
Status 3
Status 4
Door Closed
•
Machine ready to
•
operate
Solenoid de-energized
•
Door Closed
•
Machine cannot be
•
operated
Solenoid energized
•
Door Open
•
Machine cannot be
•
operated
Solenoid energized
•
Door Open
•
Machine cannot be
•
operated
Solenoid de-energized
•
Door Status
Circuit Diagram (HS5E-VA4)
Door
Closed (locked)
Closed (unlocked)
Open
Open
Contact Confi
guration
Monitor Circuit
(door closed)
11−12
ON (closed)
ON (closed)
OFF (open)
OFF (open)
Monitor Circuit
(door open)
23−24
OFF (open)
OFF (open)
ON (closed)
ON (closed)
Monitor Circuit
(locked)
41−42
ON (closed)
OFF (open)
OFF (open)
OFF (open)
Monitor Circuit
(unlocked)
53−54
OFF (open)
ON (closed)
ON (closed)
ON (closed)
Monitor Circuit
(door closed)
11−12
ON (closed)
ON (closed)
OFF (open)
OFF (open)
Monitor Circuit
(door open)
23−24
OFF (open)
OFF (open)
ON (closed)
ON (closed)
Monitor Circuit
(locked)
41−42
ON (closed)
OFF (open)
OFF (open)
OFF (open)
Monitor Circuit
(locked)
51−52
ON (closed)
OFF (open)
OFF (open)
OFF (open)
Monitor Circuit
(door closed)
11−12
ON (closed)
ON (closed)
OFF (open)
OFF (open)
Monitor Circuit
(door closed)
21−22
ON (closed)
ON (closed)
OFF (open)
OFF (open)
Monitor Circuit
(locked)
41−42
ON (closed)
OFF (open)
OFF (open)
OFF (open)
Monitor Circuit
(unlocked)
53−54
OFF (open)
ON (closed)
ON (closed)
ON (closed)
Monitor Circuit
(door closed)
11−12
ON (closed)
ON (closed)
OFF (open)
OFF (open)
Monitor Circuit
(door closed)
21−22
ON (closed)
ON (closed)
OFF (open)
OFF (open)
Monitor Circuit
(locked)
41−42
ON (closed)
OFF (open)
OFF (open)
OFF (open)
Monitor Circuit
(locked)
51−52
ON (closed)
OFF (open)
OFF (open)
OFF (open)
Solenoid Power A1-A2 (all model)
OFF (de-energized)
ON (energized)
ON (energized)
OFF (de-energized)
The above contact confi guration shows the status when the actuator is inserted and locked.
•
Monitor Circuit: Sends monitoring signals of protective door open/closed status or protective
•
door lock/unlock status.
11
23
42
54
12
24
41
53
A2
A1
(+)
(–)
A1
(–)
A2
(+)
53
41
24
12
54
42
23
11
11
23
42
54
12
24
41
53
A2
A1
(+)
(–)
HS5E- VA4
HS5E-VB4
HS5E-VC4
HS5E-VD4
24
11
23
12
42
41
54
53
51
52
41
42
12
23
11
24
22
11
21
12
41
53
41
12
11
21
22
51
54
42
52
42
Door Monitor
(Actuator Inserted)
Lock Monitor
(Solenoid OFF)
Monitor Circuit:
Monitor Circuit:
Monitor Circuit:
Monitor Circuit:
Monitor Circuit:
Monitor Circuit:
Monitor Circuit:
Monitor Circuit:
Monitor Circuit:
Monitor Circuit:
Monitor Circuit:
Monitor Circuit:
A2
(+)
A1
(–)
Unlocked with Manual
Unlocking Key
Door Closed
•
Machine cannot be
•
operated
Solenoid de-energized
•
Closed (unlocked)
ON (closed)
OFF (open)
OFF (open)
ON (closed)
ON (closed)
OFF (open)
OFF (open)
OFF (open)
ON (closed)
ON (closed)
OFF (open)
ON (closed)
ON (closed)
ON (closed)
OFF (open)
OFF (open)
OFF (de-energized)
LOCK
UNLOCK
LOCK
UNLOCK
Turn the manual
unlock key (Note)
11
23
42
54
12
24
41
53
A2
A1
(+)
(–)
Note: Actuator can be unlocked manually for confi rming the
door movement before wiring and energizing, and also for
emergency situation such as power failure.
The operation characteristics shown in the chart above are of the HS9Z-A51.
•
For other actuators, add 1.3 mm.
The operation characteristics show the contact status when the actuator enters
•
the entry slot of an interlock switch.
5.3
6.9
0 (Actuator insertion position)
26.4 (travel in mm)
3.3 (Locked position)
Monitor Circuit (unlocked, NO)
Monitor Circuit (door open, NO)
Monitor Circuit (locked, NC)
Monitor Circuit (door closed, NC)
Operation Chracteristics (reference)
Contacts OFF (open)
Contacts ON (closed)