Functional check
After installation and any fault, the safety function must be fully checked.
Proceed as follows:
Warning!
Danger of fatal injury as a result of faults in installation and functional check.
Before carrying out the functional check, make sure that there are no per-
sons in the danger area.
Observe the valid accident prevention regulations.
1. Switch on operating voltage.
The machine must not start automatically.
HS3A-H21U4 carries out a self-test.
The green STATE LED flashes for 10 s with 10 Hz.
The green STATE LED then flashes at regular intervals.
2. Close all safety guards.
The machine must not start automatically.
The green STATE LED illuminates continuously.
3. Enable operation in the control system.
4. Open the safety guard.
The machine must switch off and it must not be possible to start it as long
as the safety guard is open.
The green STATE LED flashes at regular intervals.
Repeat steps 2-4 for each safety guard.