System Manual HS3A-H21M4
28
45
40
35
30
25
20
15
10
-45
5
Z
Y
X
5
10
15
20
25
30
35
40
45
45
40
-45
35
30
25
20
15
10
5
Operating distances
Operating distance for center offset m = 0
(Only in conjunction with actuator HS9Z-ZH31 on surface mounting)
1) On surface mounting on aluminum, in a non-metallic environment the typical switching distance
increases to 30mm.
Typical operating distance
(Only in conjunction with actuator HS9Z-ZH31 on surface mounting)
Figure 14: Typical operating distance
Parameter
Value
Unit
min.
typ.
max.
Switch-on distance
-
15
1)
-
mm
Assured switch-on distance S
ao
13
-
-
Switching hysterisis
1.5
2.5
-
Assured switch-off distance S
ar
-
-
58
For a side approach direction for the actuator and safety switch,
a minimum distance of s = 6mm must be maintained so that
the operating distance of the side lobe is not entered.
Side lobe
Switch-on distance
Hysteresis
Switch-off distance
Side lobe