FOUNDATION and ANCHORING REQUIREMENTS, Fig 3
Drill holes using 3/4
”
Clean hole.
Run nut down just
Tighten nut with
carbide tipped
below impact section
Torque wrench to
masonry drill bit per
of bolt. Drive anchor
110 ft.-lbs.
ANSI standard
into hole until nut and
B94.12.1977
washer contact base.
2.3 Tools & Equipment Required
·
12 quarts of Non-Detergent / Non-Foaming Hydraulic Oil - SAE-10, AW 32 or equivalent
·
Chalk line and 12
’ Tape Measure
·
Concrete hammer drill with 3/4
” bit
·
11/16
” open end wrench
·
3/4
” open end wrench
·
Torque wrench
·
15/16
” deep socket or wrench
·
1-1/8
” socket
·
13/16
” open end wrench
·
Level (18
” minimum length)
·
Vise grips
·
Tape measure
·
Funnel
·
Hoist or Forklift (optional)
·
Two 12
’ step ladders
·
1/4
” drive ratchet with 5/16” socket