15. Filling Reservoir Tank
.
A. Remove the fill level screw of the power unit tank. Fill it with
Non-Detergent / Non-Foaming
Hydraulic Oil - SAE-10, AW 32 or equivalent
, until fluid reaches the bottom of the screw hole.
Replace the fill screw.
16. Lubricate the four inside corners of both columns with heavy duty bearing grease
.
17. Electrical Connection to Power Unit & Overhead Limit Switch
A. Have a certified electrician make the electrical connection from power supply to the power unit. Use
separate circuit for each power unit, as shown below in
(Fig. 15)
.
B. Have a certified electrician make the electrical connection for the overhead limit switch to power unit
’s
switch box, as shown in
(Fig. 15)
.
208 - 230VAC, 1PH, 60Hz
Fig. 15
Electrical Wiring must comply with local code. Protect each circuit with time delay fuse or
circuit breaker. For 208V-230V single phase, use 20 amp fuse.
Never operate the motor in line voltage less than 208VAC as motor damage may occur.