background image

 

 
 

TILT-A WAY 

HYJG 1 

VERTICAL PIVOT GATE 

SINGLE PHASE VAC, THREE PHASE VAC 

AND 24 VDC 

 

Vehicular Class 

I, II, III, and IV 

Operators & Parts Manual 

 

 

 
 
 

NOTE:  WHEN ORDERING PARTS, PLEASE HAVE YOUR SERIAL NUMBER 

 TO ENSURE THE CORRECT PARTS ARE SENT TO YOU. 

Manual subject to change with out notice. 

 

Ideal Manufacturing, Inc. •  2011 Harnish Blvd.  •  Billings, MT  59101 

P (406) 656-4360 •  F (406) 656-4363 

  
 
       $20.00  USD Funds             Date: 1/10/2020                         SERIAL NUMBER _______________________________

 

Summary of Contents for TILT-A WAY HYJG 1

Page 1: ...s Parts Manual NOTE WHEN ORDERING PARTS PLEASE HAVE YOUR SERIAL NUMBER TO ENSURE THE CORRECT PARTS ARE SENT TO YOU Manual subject to change with out notice Ideal Manufacturing Inc 2011 Harnish Blvd Bi...

Page 2: ...THREE PHASE 208 240 VAC 29 EMERGENCY STOP DIAGRAM THREE PHASE 480 VAC 30 MANUAL KEY SWITCH DIAGRAM 31 GATE OPEN INDICATOR LIGHT DIAGRAM 24 VDC 32 GATE OPEN INDICATOR LIGHT DIAGRAM SINGLE PHASE 208 24...

Page 3: ...TEM CABLE GUIDE 93 BALANCE SYSTEM CABLE SHEAVE OPTIONAL ICE SCRAPER 94 BARRIER END STANCHION PHOTO EYE SURFACE MOUNT STANCHION PHOTO EYE 95 MAGLOCK MOUNTING 96 BALANCE SYSTEM SPRING TENSIONER UNIT 97...

Page 4: ...Tilt A Way HYJG 1 Serial Number _______________ Barrier Size _______ Long _________Tall Barrier Type _________________ Notes...

Page 5: ...r requests that the part be expedited that shipping charge will be charged to the owner The part that is being warranted must be returned to Ideal Manufacturing postage prepaid When the new part is sh...

Page 6: ...se in garages or parking areas associated with a residence of one to four single families CLASS II COMMERCIAL GENERAL ACCESS VEHICULAR GATE OPERATOR 3 4 A vehicular gate operator or system intended fo...

Page 7: ...re size is very important Measure the distance from your power source to the gate operator location For wire sizes consult the NEC National Electric Code Recommended Wire Size 208 240 VAC AMPS 20 SING...

Page 8: ...IDEAL MANUFACTURING INC 3 ALTERNATE FENCE SCHEMES HYJG 1...

Page 9: ...ilt A Way HYJG vertical pivot gate has a programmable control board which allows numerous programmable functions in various combinations see programming section at in this manual The control board has...

Page 10: ...ase button SW2 to exit main menu or sub menus Button SW4 will scroll up in the menus and adjustable settings in sub menus Button SW3 will scroll down in the menus and adjustable settings in sub menus...

Page 11: ...lt DC Power In 24 Volt DC Power Out 5 amp Fuse Protected Entrapment dry contact NO Prewarn dry contacts NO and NC Aux Relay 1 dry contact NO Controller Ground Aux Relay 2 dry contact NO Aux Relay 3 dr...

Page 12: ...Logic Board Wires To Potentiometer Wires To Limit Switch s NC Wires To Motor Contactor Power In From Logic Board 2 amp Fuse HYJG 203 IDEAL MANUFACTURING INC 6 10 2015 Wires To Close Solenoid Valve Wi...

Page 13: ...1 18 PEO621 GREEN TERMINAL BLOCK 1 19 PEO622 BLACK TERMINAL BLOCK 3 20 PEO623 RED TERMINAL BLOCK 3 21 PEO665 RADIO RECEIVER optional not shown 1 22 PEO663 RADIO TRANSMITTER optional not shown as req 2...

Page 14: ...UP DOWN ENT MAIN EXIT SUB ENT SUB SAVE TILT A WAY HYJG 1 SINGLE GATE 24 VOLT DC IDEAL MANUFACTURINGINC 9...

Page 15: ...UP DOWN ENT MAIN EXIT SUB ENT SUB SAVE TILT A WAY HYJG 1 MASTER GATE 24 VOLT DC IDEAL MANUFACTURING INC 10...

Page 16: ...TILT A WAY HYJG 1 SLAVE GATE 24 VOLT DC IDEAL MANUFACTURINGINC 11...

Page 17: ...17 PEO620 END BARRIER not shown 1 18 PEO621 GREEN TERMINAL BLOCK 1 19 PEO622 BLACK TERMINAL BLOCK 2 20 PEO623 RED TERMINAL BLOCK 2 21 PEO665 RADIO RECEIVER optional not shown 1 22 PEO663 RADIO TRANSM...

Page 18: ...UP DOWN ENT MAIN EXIT SUB ENT SUB SAVE TILT A WAY HYJG 1 SINGLE GATE 240 VOLT SINGLE PHASE IDEAL MANUFACTURING INC 13...

Page 19: ...UP DOWN ENT MAIN EXIT SUB ENT SUB SAVE TILT A WAY HYJG 1 MASTER GATE 240 VOLT SINGLE PHASE IDEAL MANUFACTURING INC 14...

Page 20: ...TILT A WAY HYJG 1 SLAVE GATE 240 VOLT SINGLE PHASE IDEAL MANUFACTURING INC 15...

Page 21: ...PIN SAFETY 1 17 PEO620 END BARRIER not shown 1 18 PEO621 GREEN TERMINAL BLOCK 1 19 PEO644 BROWN TERMINAL BLOCK 2 20 PEO645 YELLOW TERMINAL BLOCK 2 21 PEO646 ORANGE TERMINAL BLOCK 2 22 100128 CONTACTOR...

Page 22: ...UP DOWN ENT MAIN EXIT SUB ENT SUB SAVE TILT A WAY HYJG 1 SINGLE GATE 240 VOLT THREE PHASE IDEAL MANUFACTURINGINC 17...

Page 23: ...UP DOWN ENT MAIN EXIT SUB ENT SUB SAVE TILT A WAY HYJG 1 MASTER GATE 240 VOLT THREE PHASE IDEAL MANUFACTURING INC 18...

Page 24: ...IDEAL MANUFACTURING INC 19 TILT A WAY HYJG 1 SLAVE GATE 240 VOLT THREE PHASE...

Page 25: ...TERMINAL BLOCK 2 22 PEO622 BLACK TERMINAL BLOCK 1 23 PEO623 RED TERMINAL BLOCK 1 24 PEO647 FUSE TERMINAL BLOCK 2 25 PEO648 FUSE 4 AMP 600 VOLT 2 26 100128 CONTACTOR 1 27 PEO280 TRANSFORMER 1PH 500 KV...

Page 26: ...21 UP DOWN ENT MAIN EXIT SUB ENT SUB SAVE TILT A WAY HYJG 1 SINGLE GATE 480 VOLT THREE PHASE IDEAL MANUFACTURING INC...

Page 27: ...IDEAL MANUFACTURINGINC 22 UP DOWN ENT MAIN EXIT SUB ENT SUB SAVE TILT A WAY HYJG 1 MASTER GATE 480 VOLT THREE PHASE...

Page 28: ...TILT A WAY HYJG 1 SLAVE GATE 480 VOLT THREE PHASE IDEAL MANUFACTURING INC 23...

Page 29: ...D RELEASE UNTIL THE DISPLAY SHOWS TIMING AND OPTIONS PRESS AND RELEASE BUTTON SW1 TO ENTER THE MENU THE DISPLAY WILL CHANGE TO TIMINGS AND OPTIONS BASIC SETTINGS CONTINUE TO PRESS AND RELEASE BUTTON S...

Page 30: ...THE SW2 BUTTON AND THE DISPLAY WILL SHOW MAIN MENU UP DOWN VIEW MENUS SELECT VIEW EDIT RESET EXIT PRESS AND RELEASE BUTTON SW4 UNTIL THE DISPLAY SHOWS TIMING AND OPTIONS PRESS AND RELEASE BUTTON SW1 T...

Page 31: ...MENU UP DOWN VIEW MENUS SELECT VIEW EDIT RESET EXIT PRESS AND RELEASE BUTTON SW4 UNTIL THE DISPLAY SHOWS TIMING AND OPTIONS PRESS AND RELEASE BUTTON SW1 TO ENTER THE MENU PRESS AND RELEASE BUTTON SW4...

Page 32: ...ot shown IDEAL MANUFACTURING INC PART NO 2 PEO606A PEO678 REF NO 1 DESCRIPTION Socket Relay HYJG 219 1 REQ NO 1 3 PEO257 Emergency Stop Button 1 6 15 2015 TILT A WAY HYJG 24 VDC EMERGENCY STOP COMPONE...

Page 33: ...NUFACTURING INC HYJG 220 6 16 2015 Relay not shown PART NO 2 PEO606A PEO678 REF NO 1 DESCRIPTION Socket Relay 1 REQ NO 1 3 PEO257 Emergency Stop Button 1 TILT A WAY HYJG 240 VAC SINGLE PHASE EMERGENCY...

Page 34: ...ANUFACTURING INC HYJG 221 6 16 2015 Relay not shown PART NO 2 PEO606A PEO678 REF NO 1 DESCRIPTION Socket Relay 1 REQ NO 1 3 PEO257 Emergency Stop Button 1 TILT A WAY HYJG 240 VAC THREE PHASE EMERGENCY...

Page 35: ...ANUFACTURING INC HYJG 222 6 16 2015 Relay not shown PART NO 2 PEO606A PEO678 REF NO 1 DESCRIPTION Socket Relay 1 REQ NO 1 3 PEO257 Emergency Stop Button 1 TILT A WAY HYJG 480 VAC THREE PHASE EMERGENCY...

Page 36: ...TILT A WAY HYJG 1 MANUAL KEY SWITCH PEO263 Manual Key Switch PART NO DESCRIPTION IDEAL MANUFACTURING INC 31 REQ NO HYJG 223 as req d 6 16 2015...

Page 37: ...NGES RELEASE THE SW2 BUTTON AND THE DISPLAY WILL SHOW MAIN MENU UP DOWN VIEW MENUS SELECT VIEW EDIT RESET EXIT PRESS AND RELEASE BUTTON SW4 UNTIL THE DISPLAY SHOWS TIMING AND OPTIONS PRESS AND RELEASE...

Page 38: ...ES RELEASE THE SW2 BUTTON AND THE DISPLAY WILL SHOW MAIN MENU UP DOWN VIEW MENUS SELECT VIEW EDIT RESET EXIT PRESS AND RELEASE BUTTON SW4 UNTIL THE DISPLAY SHOWS TIMING AND OPTIONS PRESS AND RELEASE B...

Page 39: ...ES RELEASE THE SW2 BUTTON AND THE DISPLAY WILL SHOW MAIN MENU UP DOWN VIEW MENUS SELECT VIEW EDIT RESET EXIT PRESS AND RELEASE BUTTON SW4 UNTIL THE DISPLAY SHOWS TIMING AND OPTIONS PRESS AND RELEASE B...

Page 40: ...ES RELEASE THE SW2 BUTTON AND THE DISPLAY WILL SHOW MAIN MENU UP DOWN VIEW MENUS SELECT VIEW EDIT RESET EXIT PRESS AND RELEASE BUTTON SW4 UNTIL THE DISPLAY SHOWS TIMING AND OPTIONS PRESS AND RELEASE B...

Page 41: ...TILT A WAY HYJG 1 SIREN OPERATED SENSOR DC VOLTS AND AC VOLTS SINGLE PHASE AND THREE PHASE 36 IDEAL MANUFACTURING INC Date 6 16 2016 HYJG 228 NOTE ALL INPUTS FOR FOR HYJG ARE 24 VOLT DC POSITIVE...

Page 42: ...to use some silicone around the hole to ensure no water can penetrate Water damage is not covered under warranty Note Drilling any additional holes in the enclosure indications of damage during insta...

Page 43: ...ion the sensor will open the gate once it has detected any siren or any continuous loud noise such as a loud engine for 4 5 seconds To avoid false triggers SOS suggests keeping this switch in the YLP...

Page 44: ...TILT A WAY HYJG 1 ELECTRICAL LOOP WIRING IDEAL MANUFACTURING INC 39 HYJG 229 6 17 2015...

Page 45: ...U UL LT T P PL LG G U UL LT TR RA AL LO OO OP P V Ve eh hi ic cl le e L Lo oo op p D De et te ec ct to or r Operating Instructions...

Page 46: ...or EMX exclusive Detect on Stop DOS Four frequency settings provide flexibility in preventing crosstalk in multi loop applications Cautions and Warnings This product is an accessory or part of a syst...

Page 47: ...ted on No Presence off Frequency Count flashing 5 ULTRAMETERTM Display The display shows the sensitivity setting required to detect a vehicle near the loop To use this feature observe the display whil...

Page 48: ...feature for reversing loop applications DOS On on DOS Off off Output B DIP Switch Output B is configurable for four possible modes In Pulse on Entry Exit mode Output B will be activated for approxima...

Page 49: ...ris from the finished cut with compressed air Place sand over the loop wire to the surface and pack tightly Lay new asphalt GRAVEL OR SOIL INSTALLATION While this is not a recommended installation for...

Page 50: ...setting and the second ULT PLG to the high frequency setting 4 Press the FREQUENCY COUNT RESET button to re initialize the detector and program the DIP switch settings 5 Adjust the sensitivity settin...

Page 51: ...es are properly soldered and sealed against moisture Observe ULTRAMETER display The level indicated on the display indicates residual frequency shift from vacant loop to vehicle presence Press FREQUEN...

Page 52: ...ULT PLG Operating Instructions 49 Document no 10180904 Revision 1 3 6 3 15 BLANK PAGE...

Page 53: ...ULT PLG Operating Instructions 49 Document no 10180904 Revision 1 3 6 3 15 BLANK PAGE...

Page 54: ...ULT PLG Operating Instructions 49 Document no 10180904 Revision 1 3 6 3 15 BLANK PAGE...

Page 55: ...ULT PLG Operating Instructions 50 Document no 10180904 Revision 1 3 6 3 15 BLANK PAGE...

Page 56: ...ocument no 10180904 Revision 1 3 6 3 15 4564 Johnston Parkway Cleveland Ohio 44128 United States of America www emxinc com Technical Support 216 834 0761 technical emxinc com Sales 216 518 9888 Fax 21...

Page 57: ...SCROLL THRU THE SUBMENU UNTIL THE SLOT THAT YOU WANT TO ACCESS IS SHOW PRESS AND RELEASE BUTTON SW1 TO ENTER USE BUTTON SW4 TO SCROLL THRU THE FUNCTION ASSIGNMENTS UNTIL THE DESIRE FUNCTION IS SHOW PR...

Page 58: ...ANUFACTURING INC REF NO PEO272 PEO273B 1 2 DESCRIPTION Radio Transmitter 1 Button Model 811LM Radio Receiver Model 850LM 53 REQ NO Date 3 24 2016 HYJG 231 1 as req 3 PEO273A Radio Transmitter 3 Button...

Page 59: ...NG INC REF NO PEO272 PEO273B 1 2 DESCRIPTION Radio Transmitter 1 Button Model 811LM Radio Receiver Model 850LM 54 REQ NO Date 3 24 2016 HYJG 232 1 as req 3 PEO273A Radio Transmitter 3 Button Model 813...

Page 60: ...ATH the use of CONSTANT OPERATION on residential openers is PROHIBITED When a receiver is used to activate a commercial door opener a reversing edge MUST be installed on the bottom of the door Failure...

Page 61: ...n 30 seconds press and hold the button on the remote control that you wish to program to the receiver 3 Release the remote control button when the LED on the receiver blinks then turns off Programming...

Page 62: ...EMENT AVERTISSEMENT AVERTISSEMENT AVERTISSEMENT Pour pr venir le risque de BLESSURES GRAVES ou de D C S il est INTERDIT d utiliser les ouvre porte r sidentiels EN FONCTIONNEMENT CONTINUEL Avant d util...

Page 63: ...llume et reste allum pendant 30 secondes 2 Dans les 30 secondes presser et maintenir enfonc le bouton de la t l commande programmer pour ce r cepteur 3 Le t moin du r cepteur se met clignoter puis s t...

Page 64: ...switches in an existing remote control GATE KEY REMOTE CONTROLS MODELS 811LM AND 813LM Set the Dip Switches 1 Slide the cover open to access the dip switches in the remote control 2 Use a pen or screw...

Page 65: ...AL SUPPORT DIAL OUR TOLL FREE NUMBER 1 800 528 9131 www liftmaster com NOTICE To comply with FCC and or Industry Canada IC rules adjustment or modifications of this transceiver are prohibited THERE AR...

Page 66: ...rs DIP de la nouvelle t l commande aux commutateurs DIP de la t l commande existante T L COMMANDES CL D OUVERTURE DE BARRI RE MOD LES 811LM ET 813LM R glage des commutateurs DIP 1 Ouvrez le couvercle...

Page 67: ...ISTANCE TECHNIQUE COMPOSER NOTRE NUM RO GRATUIT 1 800 528 9131 www liftmaster com 2013 The Chamberlain Group Inc All Rights Reserved 114A4298B Tous droits r serv s AVIS Les r gles de la FCC et ou d In...

Page 68: ...rical Conduit with 2 1 2 projection above Concrete PART NO 5 8 6 7 N A N A NA N A REF NO 1 4 3 2 N A 1 2 Hex Nut Remote Control Station of Choice 1 2 Lock Washer Included are bolts nuts keys and plate...

Page 69: ...1 1 Junction Box 6 N A 18 5 S O Cord AS REQ Close safety with resistor Closing Edge Holding Track Length is required TILT A WAY HYJG 1 MONITORED REVERSING EDGE INSTALLATION IDEAL MANUFACTURING INC 64...

Page 70: ...Screw Reversing Edge Rubber Strip Length is required Insert in track from front C Switch Order length as required Insert in track from front 3 24 2016 CONNECT CLOSING TAPE SWITCH BLACK WIRE TO TERMIN...

Page 71: ...r input asserted Input state timer hold Input clear Input asserted Input state aux timer Input cleat Input asserted Input state UL reset on board Input clear Input asserted Input state remote N O cont...

Page 72: ...ng the cycle to enter a proper setting in the safety threshold submenu leaf 1 Leaf 2 maximum deviation threshold last cycle gate stopped X X A gate stopped Motor Current Leaf 1 gate moving Approx Moto...

Page 73: ...monthly 0 0 A to 20 0 A Motor inrush ignore period factory set 1 0 seconds 0 0 seconds to 2 0 seconds Position Feedback Obstruction Detect for hydraulic gate only factory set Enabled Disabled Enabled...

Page 74: ...it switch pulse aux relay on open limit switch pulse aux relay on open motion pulse aux relay on close motion hold aux relay on close limit switch hold aux relay on open limit switch hold aux relay on...

Page 75: ...functionality assignment J3 slot loop slot disabled safety loop free exit loop shadow loop arming loop Loop functionality assignment J5 slot loop slot disabled safety loop free exit loop shadow loop...

Page 76: ...use only Caution Apply volts and trim calibration 24 0 volts Caution Zero life time cycle counter no yes Caution Reset all settings to defaults no yes Statistics o Gate Cycle Count Total gate life ti...

Page 77: ...BLANK PAGE FOR NOTES...

Page 78: ...OR RIGHT HAND GATE 1 FGO404 2 LEFT INNER GUARD FOR LEFT HAND GATE 1 FGO404A 3 RIGHT INNER GUARD FOR RIGHT HAND GATE 1 FGO405 4 RIGHT INNER GUARD FOR LEFT HAND GATE 1 FGO405A 5 TOP COVER DOOR SIDE 1 FG...

Page 79: ...er completely you can restore the Lynch factory settings by rotating SELECT to rFP and then rotate ADJUST up past 10 for the display to reset NOTE for Step 9 You may have to adjust your Input Signal S...

Page 80: ...UB SAVE TILT A WAY HYJG 1 PROPORTIONAL VALVE DIAGRAM NOT ALL COMPONENTS AND WIRES SHOWN FOR CLARITY 24 VOLT DC UNIT SHOWN USE SAME PROCEDURE FOR AC UNIT IDEAL MANUFACTURINGINC 74 ENCLOSURE HYDRAULIC P...

Page 81: ...inder Heating Strip IDEAL MANUFACTURING INC PART NO 2 TWO462 100135 100134 4 3 PEO247 REF NO 1 Hydraulic Pump Reservoir Insulating Cover 75 DESCRIPTION In Tank Oil Heater with Thermostat 120 VAC Date...

Page 82: ...Cover Cylinder Heating Strip IDEAL MANUFACTURING INC PART NO 2 TWO520 100135 100134 4 3 PEO247 REF NO 1 Hydraulic Pump Reservoir Insulating Cover 76 DESCRIPTION In Tank Oil Heater with Thermostat Date...

Page 83: ...r Insulating Cover Cylinder Heating Strip IDEAL MANUFACTURING INC PART NO 2 TWO520 100135 100134 4 3 PEO247 REF NO 1 Hydraulic Pump Reservoir Insulating Cover 77 DESCRIPTION In Tank Oil Heater with Th...

Page 84: ...uminum ID1066 2 4 material and in varied lengths and heights When contacting manufacturer regarding a TILT A Way gate always provide complete serial number 3 16 x 2 1 2 Stainless Steel Cotter Pin 3 pe...

Page 85: ...otate barrier carriage to down position Remove pivot shaft with attached components Install barrier and secure to vertical carriage post with five bolts and one bolt at outer end of carriage horizonta...

Page 86: ...MODEL HYJG HYDRAULIC VERTICAL PIVOT GATE IDEAL MANUFACTURING INC...

Page 87: ...aced in open position 2 Any adjustment preformed on cable sheave must be preceded by the release of all cable tension at spring connections CONDITIONS AND SOLUTIONS 1 Condition Gate heavy at both up a...

Page 88: ...IDEAL MANUFACTURING INC 82 TILT A WAY HYDRAULIC VERTICAL PIVOT GATE HYJG BALANCE SYSTEM ADJUSTMENT DATE 3 24 2016 HYJG 242...

Page 89: ...4 2016 DWG NO HYJG 243 TITLE HYJG 1 SPRING REPLACEMENT SIZE C SCALE Ideal Mfg Inc REV 2011 Harnish Blvd Billings MT 59101 Tel 406 656 4360 1 2 3 4 6 5 7 8 SAFETY ROD PAINT MARK SAFETY SWITCH SPRING CA...

Page 90: ...eye Secure with cotter pin Be sure that the safety switch plate is aligned with safety switch when tension springs are tightened ref 8 Turn tension spring nut clockwise until upper spring end reaches...

Page 91: ...on If gate moves see page 68 for balance adjustment Close manual valves and turn power on Return gate to closed position 5 Inspect balance cables for broken strands Replace cable if there are five bro...

Page 92: ...G 244 TITLE HYJG 1 GENERAL ARRANGEMENT SIZE C SCALE Ideal Mfg Inc REV 2011 Harnish Blvd Billings MT 59101 Tel 406 656 4360 5 C A 6 7 8 9 B 3 4 10 11 12 1 SAFETY ROD STORAGE LOCATION REF 2 BARRIER NOT...

Page 93: ...ng 2 3 N A 1 2 Hex Nut 4 4 N A 1 2 Lock Washer 4 5 N A 1 2 SAE Flat Washer 4 6 N A 1 2 X 4 1 2 Flat Head Bolt 4 7 N A 1 SAE Flat Washer 4 8 ID1006 3 16 X 1 1 2 Stainless Cotter Pin 2 9 N A 5 8 Nylock...

Page 94: ...AGE SIZE C SCALE Ideal Mfg Inc REV 2011 Harnish Blvd Billings MT 59101 Tel 406 656 4360 8 7 7 10 9 9 10 1C 2 11 12 17 17 16 13 18 11 12 6 2 5 4 3 15 14 14 15 16 17 17 12 11 2 11 12 18 13 6 9 10 7 8 7...

Page 95: ...1 1 1 2 6 Hex Jam Nut 18 NA 6 1 2 13 Hex Nut 19 NA 6 1 2 Lock Washer 20 NA 6 1 2 13 X 1 3 4 Hex Bolt 21 NA 3 1 2 13 X 1 1 4 Hex Bolt 22 NA 1 6 ORB X 6 FJIC LONG 90 DEG 23 NA 1 6 ORB X 6 FJIC 90 DEG 2...

Page 96: ...OTHER WISE SPECIFIED DIMENSIONS ARE IN INCHES TOLERANCES ARE XX 01 XXX 005 FRACTION 1 32 ANGLES 1 DRILLED HOLE 1 64 2011 Harnish Blvd Billings MT 59101 A B TILT A WAY HYJG 1 CYLINDER WITH COMPONENTS R...

Page 97: ...L THE DISPLAY SHOWS TIMING AND OPTIONS PRESS AND RELEASE BUTTON SW1 TO ENTER THE MENU THE DISPLAY WILL CHANGE TO TIMINGS AND OPTIONS BASIC SETTINGS CONTINUE TO PRESS AND RELEASE BUTTON SW4 UNTIL THE D...

Page 98: ...mass PROJECTION REMOVE ALL BURRS UNLESS OTHER WISE SPECIFIED DIMENSIONS ARE IN INCHES TOLERANCES ARE XX 01 XXX 005 FRACTION 1 32 ANGLES 1 DRILLED HOLE 1 64 2011 Harnish Blvd Billings MT 59101 PARTS LI...

Page 99: ...AY HYDRAULIC VERTICAL PIVOT GATE HYJG 1 BALANCE SYSTEM CABLE GUIDE PART NO IDEAL MANUFACTURING INC 4 IDI006 FGO127 FGO707 FGO128 REF NO 2 3 1 3 16 x 1 1 2 Stainless Cotter Pin 93 Plastic Roller DESCRI...

Page 100: ...ring TWO106 3 2 SHEAV SHAFT TWO103 4 2 1 2 13 NYLOCK HEX NUT N A 5 1 TENSION CABLE 72 1 2 TWO110 1 6 4 TENSION CABLE 95 1 2 TWO110 2 7 2 1 2 13 HEX NUT optional N A 8 2 ICE SCRAPER BOLT optional PEO45...

Page 101: ...REF NO 1 5 4 3 2 FGO172 Photo Eye 95 DESCRIPTION Stanchion Unit Date 3 25 2016 HYJG 254 2 REQ NO 1 N A PEO454 N A N A 1 REQ NO 4 Surface Mount Stanchion Unit DESCRIPTION 3 4 x 6 Exposed Bolts 5 16 Hex...

Page 102: ...Socket Head Cap Screw 5 16 24 X 2 1 N A 7 ARMATURE SPACER 1 N A 8 SEX NUT 1 N A 9 SPRING 1 POO194 10 CONDUIT COUPLER 1 PEO279 1 11 1 2 STEEL STRIAN RELEAF 2 PEO279 12 PLUG BUTTON 4 N A 13 STANCHION 1...

Page 103: ...2500 Pound White As required 4 Front Spring Connector FGO168 500 or 1000 Pound Spring 2 FGO170 1500 or 1750 Pound Spring 2 FGO171 2000 or 2500 Pound Spring 2 5 TWO104 Clevis Pin 2 6 Rear Spring Conne...

Page 104: ...4 3 25 2016 DWG NO HYJG 251 TITLE HYJG BALANCE SYSTEM SPRING TENSIONER UNIT SIZE C SCALE IDEAL MFG INC REV Billings MT 59101 2011 Harnish Blvd Tel 406 656 4360 17 14 18 10 9 13 15 12 6 4 1 16 5 3 8 11...

Page 105: ...oir Set Three Phase 1 3 TWO528 6 MORB X 6 MJIC Adapter 2 4 TWO402 Short 3 8 Pressure Hose 36 1 5 TWO164 Long 3 8 Pressure Hose 87 1 6 TWO579 90 degree Elbow 1 7 TWO578 90 degree Elbow long 1 8 TWO520...

Page 106: ...IDEAL MANUFACTURING INC Date 3 25 2016 HYJG 252 TILT A WAY HYDRAULIC VERTICAL PIVOT GATE HYDRAULIC SYSTEM HYJG 1 100...

Page 107: ...THERMOSTAT 120 VAC HEATER W THERMOSTAT DC UNIT 1 12 TWO523 BY PASS VALVE 2 13 TWO522 PRESSURE RELIEF VALVE 1 14 TWO526 12 MORB X 16 HOSE BARB ADAPTER 1 15 TWO528 6 MORB X 6 MJIC ADAPTER 3 16 TWO529 8...

Page 108: ...HYJG 1 HYDRAULIC UNIT SIZE C SCALE Ideal Mfg Inc REV 2011 Harnish Blvd Billings MT 59101 Tel 406 656 4360 11 8 9 100140 14 25 18 15 27 26 22 2 16 4 5 20 13 30 6 12 28 7 29 12 19 1 10 24 23 23 24 23 3...

Page 109: ...e if shorted Gate closed and will not open Full Closed Schedule Lockout P1 CAN1 I3 Lockout Schedule active Turn lockout schedule off in menu Gate closed and will not open Full Closed Low Voltage Secur...

Page 110: ...n loop is active Clear input to I8 Reveres open loop Gate opened and will not close Full Open Pending Auto Close P1 CAN1 I3 I9 Aux 1 input is active Clear input to I9 Aux 1 input Gate opened and will...

Page 111: ...t settings Gate stops and reveres and stops during closing cycle Stopped mid travel P1 CAN1 I3 Position Feedback Potentiometer has failed loose wire connections or improper wire connections Gate stops...

Page 112: ...une r sidence de un quatre familles monoparentales CLASSE II COMMERCIAL GENERAL acc s v hiculaire PORTAIL 3 4 Un op rateur de v hicule de grille ou syst me destin tre utilis dans un emplacement commer...

Page 113: ...s les p riph riques Ne pas effectuer le soudage alors que le c ble moteur est connect la carte de contr le ou la batterie connect e graves dommages la carte de commande et la batterie se produira Atte...

Page 114: ...U UL LT T P PL LG G U UL LT TR RA AL LO OO OP P D D t te ec ct te eu ur r d de e b bo ou uc cl le e d de e v v h hi ic cu ul le e Mode d emploi...

Page 115: ...rte L ULT PLG peut tre utilis dans le centre en s curit et sortie bouclent postes Fonction d affichage du The UltraMETER installation facile en affichant le r glage optimal requis pour d tecter un v h...

Page 116: ...uivi environnemental Compensation automatique Protection contre les surtensions Boucle des circuits prot g s par des suppresseurs de surtension D tecter la sortie tat solide Sortie B tat solide B sort...

Page 117: ...x pour voir cet effet Changez la fr quence pour viter la diaphonie R glage de la sensibilit ity setting L interrupteur rotatif 10 broches permet un r glage pr cis du niveau de d tection Le niveau de s...

Page 118: ...is function requires that a vehicle come to a complete stop on the loop for the output to activate This feature is useful in cases where cross traffic causes the detection Sortie B Param tres de sorti...

Page 119: ...le nombre de fr quences r Initialise apr s d pouillement DIP Position de l interrupteur 8 ASB a permis sur ASB hors hors DIP Position de l interrupteur 7 NORMAL sur INFINI hors DIP Position de l inte...

Page 120: ...e 100 m gohms 2 V rifier les connexions de boucle aux bornes 3 Les pissures de cocher sont correctement soud s et tanche l humidit 4 Affichage ULTRAMETER observer niveau indiqu sur l affichage indique...

Page 121: ...la scie Placer le mat riau de backer dans la scie entaille au dessus de la boucle et le pack troitement Placez un scellant de qualit sur la scie coupe afin de sceller la surface REFAIRE SURFACE ASPHA...

Page 122: ...ULT PLG Operating Instructions 48 Document no 10180904 Revision 1 3 6 3 15 Informations de commande ULT PLG ULTRALOOP v hicule d tecteur de boucle Accessories PR XX EMX Lite pr form Loops Garantie...

Page 123: ...ULT PLG Operating Instructions 49 Document no 10180904 Revision 1 3 6 3 15 BLANK PAGE...

Page 124: ...ULT PLG Operating Instructions 50 Document no 10180904 Revision 1 3 6 3 15 BLANK PAGE...

Page 125: ...ocument no 10180904 Revision 1 3 6 3 15 4564 Johnston Parkway Cleveland Ohio 44128 United States of America www emxinc com Technical Support 216 834 0761 technical emxinc com Sales 216 518 9888 Fax 21...

Page 126: ...ntr e distance n de contact Contact ouvert Contact ferm Etat d entr e distance N C de contact Contact ouvert Contact ferm fente de la boucle d tat d entr e J3 Input clair Input affirm fente de la bouc...

Page 127: ...0 volts Feuille 2 24 0 volts o TIMING ET OPTIONS Dans ce menu vous pouvez r gler les param tres de l utilisateur o R glages de base heure de l horloge actuelle r gl e en usine en temps de montagne 12...

Page 128: ...tr e minuterie terminale jeu entr e I7 Entr e verrouillage permet annexe 1 Activ D sactiv Horaire de d but de verrouillage d entr e 1 fix pour le temps de commencer lockout am ou pm et jour de la sema...

Page 129: ...ux relais ouverts mouvement impulsion aux relais proximit mouvement tenir aux relais fermer l interrupteur de fin de course tenir aux relais de fin de course d ouverture tenir aux relais mouvement d o...

Page 130: ...ervice o Lockout Service D finir un lock out de service pour tout l entretien contr leur activ d sactiv du contr leur portail ne bouge pas o rappels Maintenance entretien de rappel de service non n ce...

Page 131: ...71 journaux d v nements General Event Log Event 1 most recent S curit Event Log Event 1 le plus r cent...

Reviews: