EMX Industries, Inc.
Tech support: 216-834-0761
5/6
ULT-PLG_Rev1.8_082619 [email protected]
Installation
1.
Plug the ULT-PLG into the operator according to instructions provided by the manufacturer.
2.
Configure the DIP switches according to preferences. Refer to Settings & Display for
more information.
3.
If using multiple loops or suspect crosstalk/interference from the environment, perform a
frequency count on each detector to confirm that the operation frequencies are different.
•
Press the FREQUENCY COUNT / RESET button and count the number of flashes of the
red LED. Each flash represents 10kHZ. Counts from 3 to 13 confirm that the detector
is tuned to a loop.
•
If multiple loops and detectors are utilizing the same or very similar frequency,
configure DIP switches 7 and 8 on one of the devices. For example: Move one ULT-PLG
to the low frequency setting and the second ULT-PLG to the high frequency setting.
4.
Press the FREQUENCY COUNT / RESET button to re-initialize the detector and program the
DIP switch settings.
5.
Adjust the sensitivity setting to desired level to assure detection of all vehicle traffic.
•
To test the sensitivity, without moving the sensing loop, drive a vehicle near the loop.
When the vehicle is first detected by the loop, “9” will be displayed on the ULTRAMETER™
display. Position the vehicle over the loop where the detection point is desired, take note
of the number displayed on the ULTRAMETER
™
and change the sensitivity setting
(10-position rotary switch) to match that number.
•
Move the test vehicle away from the loop to remove it from the detection zone
(ULTRAMETER
™
display should be blank).
•
Press the FREQUENCY COUNT / RESET button on the ULT-PLG.
•
Retest the product by moving the vehicle into and out of the detection zone to make sure
the set-up and location are working as intended.
6.
Press the FREQUENCY COUNT BUTTON / RESET button to calibrate the ULT-PLG to the loop.
TIP:
Summary of Contents for TILT-A WAY HYJG 1
Page 8: ...IDEAL MANUFACTURING INC 3 ALTERNATE FENCE SCHEMES HYJG 1...
Page 16: ...TILT A WAY HYJG 1 SLAVE GATE 24 VOLT DC IDEAL MANUFACTURINGINC 11...
Page 20: ...TILT A WAY HYJG 1 SLAVE GATE 240 VOLT SINGLE PHASE IDEAL MANUFACTURING INC 15...
Page 24: ...IDEAL MANUFACTURING INC 19 TILT A WAY HYJG 1 SLAVE GATE 240 VOLT THREE PHASE...
Page 28: ...TILT A WAY HYJG 1 SLAVE GATE 480 VOLT THREE PHASE IDEAL MANUFACTURING INC 23...
Page 44: ...TILT A WAY HYJG 1 ELECTRICAL LOOP WIRING IDEAL MANUFACTURING INC 39 HYJG 229 6 17 2015...
Page 52: ...ULT PLG Operating Instructions 49 Document no 10180904 Revision 1 3 6 3 15 BLANK PAGE...
Page 53: ...ULT PLG Operating Instructions 49 Document no 10180904 Revision 1 3 6 3 15 BLANK PAGE...
Page 54: ...ULT PLG Operating Instructions 49 Document no 10180904 Revision 1 3 6 3 15 BLANK PAGE...
Page 55: ...ULT PLG Operating Instructions 50 Document no 10180904 Revision 1 3 6 3 15 BLANK PAGE...
Page 77: ...BLANK PAGE FOR NOTES...
Page 86: ...MODEL HYJG HYDRAULIC VERTICAL PIVOT GATE IDEAL MANUFACTURING INC...
Page 123: ...ULT PLG Operating Instructions 49 Document no 10180904 Revision 1 3 6 3 15 BLANK PAGE...
Page 124: ...ULT PLG Operating Instructions 50 Document no 10180904 Revision 1 3 6 3 15 BLANK PAGE...