IDEAL MANUFACTURING INC.
52
HYJG-230
TILT-A-WAY HYJG 1
LOOP DETECTOR SOCKET DIAGRAM
3/24/2016
LOGIC BOARD
TILT-A-WAY HYJG
THERE ARE THREE LOOP SLOTS J3, J5, AND J7 THAT CAN BE PROGRAMMED FOR SEVERAL DIFFERENT FUNCTIONS
LOOP SLOT DISABLED / SAFETY LOOP / FREE EXIT LOOP / SHADOW LOOP / ARMING LOOP
TO ACCESS THESE FUNCTIONS PRESS AND HOLD BUTTON SW2 ON THE INTERFACE BOARD FOR ABOUT 4 SECONDS
UNTIL THE DISPLAY CHANGES TO SHOW
MAIN MENU
UP / DOWN - VIEW MENUS
SELECT - VIEW / EDIT
RESET - EXIT
PRESS AND RELEASE BUTTON SW4 UNTIL THE DISPLAY CHANGES TO
TIMING AND OPTIONS
PRESS AND RELEASE BUTTON SW1 TO ENTER THIS MENU
PRESS AND RELEASE BUTTON SW4 UNTIL THE DISPLAY SHOWS
LOOP AND REMOTE ASSIGNMENT
PRESS AND RELEASE BUTTON SW1 TO ENTER SUBMENU
THE DISPLAY WILL SHOW
LOOP FUNCTIONALITY ASSIGNMENT J3 SLOT
USE BUTTON SW4 TO SCROLL THRU THE SUBMENU UNTIL THE SLOT THAT YOU WANT TO ACCESS IS SHOW
PRESS AND RELEASE BUTTON SW1 TO ENTER
USE BUTTON SW4 TO SCROLL THRU THE FUNCTION ASSIGNMENTS UNTIL THE DESIRE FUNCTION IS SHOW
PRESS AND RELEASE BUTTON SW1 TO SAVE
USE BUTTON SW4 TO CHANGE TO THE NEXT LOOP SLOT TO BE PROGRAMMED AND REPEAT
TO ASSIGN FUNCTIONS TO ALL SLOTS USED
WHEN ALL SLOTS HAVE BEEN PROGRAMMED PRESS AND RELEASE BUTTON SW2 TO EXIT SUBMENU
REPEAT UNTIL YOU HAVE EXITED ALL MENUS
SAFETY LOOP
WILL STOP AND REVERSE A CLOSING GATE, AND HOLD AN OPEN GATE OPEN UNTIL CLEARED
FREE EXIT
WILL OPEN A CLOSED GATE AND STOP AND REVERSE A CLOSING GATE AND HOLD IT OPEN UNTIL CLEARED
SHADOW LOOP
WILL HOLD OPEN A FULLY OPENED GATE UNTIL CLEARED
ARMING LOOP
WILL LATCH AN AUXILIARY OUTPUT RELAY IF THE AUXILIARY OUTPUT RELAY FUNCTION
HOLD AUX RELAY ON ARMING LOOP ASSERTION
HAS BEEN SELECTED IN THE
AUXILIARY I / O
SUBMENU IN
TIMING AND OPTIONS
MENU
PLUG IN DETECTOR
AS PICTURED
BE SURE POWER IS OFF
BEFORE PLUGGING IN
LOOP SLOTS
Summary of Contents for TILT-A WAY HYJG 1
Page 8: ...IDEAL MANUFACTURING INC 3 ALTERNATE FENCE SCHEMES HYJG 1...
Page 16: ...TILT A WAY HYJG 1 SLAVE GATE 24 VOLT DC IDEAL MANUFACTURINGINC 11...
Page 20: ...TILT A WAY HYJG 1 SLAVE GATE 240 VOLT SINGLE PHASE IDEAL MANUFACTURING INC 15...
Page 24: ...IDEAL MANUFACTURING INC 19 TILT A WAY HYJG 1 SLAVE GATE 240 VOLT THREE PHASE...
Page 28: ...TILT A WAY HYJG 1 SLAVE GATE 480 VOLT THREE PHASE IDEAL MANUFACTURING INC 23...
Page 44: ...TILT A WAY HYJG 1 ELECTRICAL LOOP WIRING IDEAL MANUFACTURING INC 39 HYJG 229 6 17 2015...
Page 52: ...ULT PLG Operating Instructions 49 Document no 10180904 Revision 1 3 6 3 15 BLANK PAGE...
Page 53: ...ULT PLG Operating Instructions 49 Document no 10180904 Revision 1 3 6 3 15 BLANK PAGE...
Page 54: ...ULT PLG Operating Instructions 49 Document no 10180904 Revision 1 3 6 3 15 BLANK PAGE...
Page 55: ...ULT PLG Operating Instructions 50 Document no 10180904 Revision 1 3 6 3 15 BLANK PAGE...
Page 77: ...BLANK PAGE FOR NOTES...
Page 86: ...MODEL HYJG HYDRAULIC VERTICAL PIVOT GATE IDEAL MANUFACTURING INC...
Page 123: ...ULT PLG Operating Instructions 49 Document no 10180904 Revision 1 3 6 3 15 BLANK PAGE...
Page 124: ...ULT PLG Operating Instructions 50 Document no 10180904 Revision 1 3 6 3 15 BLANK PAGE...