EMX Industries, Inc.
Tech support: 216-834-0761
2/6
ULT-PLG_Rev1.8_082619 [email protected]
Wiring Connections
Settings & Display
1. DIP Switch
The DIP switch settings are explained on the next page.
2.
Sensitivity Setting
The 10-position rotary switch allows for adjustment of detection threshold.
The sensitivity threshold increases from position 0 (lowest setting)
through 9 (highest setting). Typical applications require a setting of 3 or 4.
The rotary adjustment must be set to a specific/whole number.
There are no half settings.
3. Power / Loop Fault Indicator (Green LED)
Normal Operation
on
Upon power up, the detector
initializes by automatically tuning to
the loop. The green LED indicates
that the detector is powered and
operational.
Shorted or Open Loop
fast flash
Previous Loop Fault
flashes fast twice
intermittently
4. Detect / Frequency Count (Red LED)
Presence Detected
on
No Presence
off
Frequency Count
flashing
5. ULTRAMETER
TM
Display
The display shows the sensitivity setting required to detect a vehicle near the loop. To use this feature,
observe the display while a vehicle is moving into position near the loop, note the number displayed,
then adjust the sensitivity setting to the displayed position. The display will adjust from
9 for a weak signal to 0 for a very strong signal. During normal operation, when a vehicle is not on
or near the loop, the display is blank. The effects of cross-traffic interference can be observed on the
display when the sensing area is vacant.
6. Frequency Count / Reset Button
Press and release the frequency count button and count the number of flashes on the red LED.
Each flash represents 10 kHz. Following a frequency count cycle, the detector re-initializes.
10 Pin Female Connector
Connector Pin
Description
1
Loop Connection
2
Loop Connection
3
Power + (12-24 VDC)
4
No Connection
5
No Connection
6
Output B
7
Output B Inverted
8
Presence Output
9
Power + (12-24 VDC)
10
Ground
3
4
6
5
1
2
6
5
3
4
2
1
Summary of Contents for TILT-A WAY HYJG 1
Page 8: ...IDEAL MANUFACTURING INC 3 ALTERNATE FENCE SCHEMES HYJG 1...
Page 16: ...TILT A WAY HYJG 1 SLAVE GATE 24 VOLT DC IDEAL MANUFACTURINGINC 11...
Page 20: ...TILT A WAY HYJG 1 SLAVE GATE 240 VOLT SINGLE PHASE IDEAL MANUFACTURING INC 15...
Page 24: ...IDEAL MANUFACTURING INC 19 TILT A WAY HYJG 1 SLAVE GATE 240 VOLT THREE PHASE...
Page 28: ...TILT A WAY HYJG 1 SLAVE GATE 480 VOLT THREE PHASE IDEAL MANUFACTURING INC 23...
Page 44: ...TILT A WAY HYJG 1 ELECTRICAL LOOP WIRING IDEAL MANUFACTURING INC 39 HYJG 229 6 17 2015...
Page 52: ...ULT PLG Operating Instructions 49 Document no 10180904 Revision 1 3 6 3 15 BLANK PAGE...
Page 53: ...ULT PLG Operating Instructions 49 Document no 10180904 Revision 1 3 6 3 15 BLANK PAGE...
Page 54: ...ULT PLG Operating Instructions 49 Document no 10180904 Revision 1 3 6 3 15 BLANK PAGE...
Page 55: ...ULT PLG Operating Instructions 50 Document no 10180904 Revision 1 3 6 3 15 BLANK PAGE...
Page 77: ...BLANK PAGE FOR NOTES...
Page 86: ...MODEL HYJG HYDRAULIC VERTICAL PIVOT GATE IDEAL MANUFACTURING INC...
Page 123: ...ULT PLG Operating Instructions 49 Document no 10180904 Revision 1 3 6 3 15 BLANK PAGE...
Page 124: ...ULT PLG Operating Instructions 50 Document no 10180904 Revision 1 3 6 3 15 BLANK PAGE...