EMX Industries, Inc.
Tech support: 216-834-0761
1/6
ULT-PLG_Rev1.8_082619 [email protected]
ULT-PLG
™
Plug-In Vehicle Loop Detector
Instruction Manual
The ULT-PLG plug-in style vehicle loop detector senses metallic objects near an induction loop.
This vehicle detector may be used in center, reverse and exit loop positions. The ULTRA
METER™ display
allows for easy set-up by displaying the optimum sensitivity setting for detecting a vehicle near the loop
while ignoring interference. Ten sensitivity settings allow for fine adjustment of the detection level.
The ULT-PLG features a user configurable Output B for fail safe/secure, pulse on entry/exit, presence or
EMX exclusive, Detect-on-Stop
™
(DOS
®
). Four frequency settings provide flexibility in preventing crosstalk
in multi-loop applications.
Cautions and Warnings
This product is an accessory or part of a system. Install the ULT-PLG according to
instructions from the gate or door operator manufacturer. Comply with all applicable
codes and safety regulations.
Specifications
Ordering Information
•
ULT-PLG
Plug-in vehicle loop detector (included)
•
PR-XX
Lite preformed loop (XX
–
specify size)
•
TSTL
Test loop, troubleshooting tool
Power
12-24 VDC
Draw Current
15 mA
Loop Frequency
4 settings (low, med-low, med-hi, high)
Loop Inductance Range
20-
2000 µH (Q factor ≥ 5)
Surge Protection
Loop circuitry protected by surge suppressors
Operating Temperature
-40º to 180ºF (-40º to 82ºC) 0 to 95% relative humidity
Connector
10 pin female
Dimensions (L x W x H)
3.0” (76 mm) x 0.9” (22 mm) x 2.75” (70 mm)
Summary of Contents for TILT-A WAY HYJG 1
Page 8: ...IDEAL MANUFACTURING INC 3 ALTERNATE FENCE SCHEMES HYJG 1...
Page 16: ...TILT A WAY HYJG 1 SLAVE GATE 24 VOLT DC IDEAL MANUFACTURINGINC 11...
Page 20: ...TILT A WAY HYJG 1 SLAVE GATE 240 VOLT SINGLE PHASE IDEAL MANUFACTURING INC 15...
Page 24: ...IDEAL MANUFACTURING INC 19 TILT A WAY HYJG 1 SLAVE GATE 240 VOLT THREE PHASE...
Page 28: ...TILT A WAY HYJG 1 SLAVE GATE 480 VOLT THREE PHASE IDEAL MANUFACTURING INC 23...
Page 44: ...TILT A WAY HYJG 1 ELECTRICAL LOOP WIRING IDEAL MANUFACTURING INC 39 HYJG 229 6 17 2015...
Page 52: ...ULT PLG Operating Instructions 49 Document no 10180904 Revision 1 3 6 3 15 BLANK PAGE...
Page 53: ...ULT PLG Operating Instructions 49 Document no 10180904 Revision 1 3 6 3 15 BLANK PAGE...
Page 54: ...ULT PLG Operating Instructions 49 Document no 10180904 Revision 1 3 6 3 15 BLANK PAGE...
Page 55: ...ULT PLG Operating Instructions 50 Document no 10180904 Revision 1 3 6 3 15 BLANK PAGE...
Page 77: ...BLANK PAGE FOR NOTES...
Page 86: ...MODEL HYJG HYDRAULIC VERTICAL PIVOT GATE IDEAL MANUFACTURING INC...
Page 123: ...ULT PLG Operating Instructions 49 Document no 10180904 Revision 1 3 6 3 15 BLANK PAGE...
Page 124: ...ULT PLG Operating Instructions 50 Document no 10180904 Revision 1 3 6 3 15 BLANK PAGE...