SAFETY

Current Gas Safety (Installation & Use) Regulations or Rules in
Force 

impose certain statutory obligations on gas users.  This

appliance must be installed by a CORGI registered installer, or
in IE a competent person, in accordance with the above
regulations.

1.

It is ESSENTIAL that the instructions in this booklet are
strictly followed, for safe, economical operation of the boiler.

1

CONTROLS OPERATION AND DISPLAY

2.

Do not obstruct ventilation ducts, grilles or openings in the
boiler room, or the passage of combustion and ventilation
out to the boiler.

3.

Do not store objects around or on the boiler, and keep
access clear at all times.

4.

Flammable materials must not be placed in close proximity
to the boiler.  Materials giving off vapours must not be stored
in the same room as the boiler.

5.

A dust free environment should be maintained in the room
containing the boiler.

6.

Do not turn off the boiler if it is to be left unattended in frosty
weather.

7.

The boiler must not be operated without the casing correctly
fitted.

8.

If it is known or suspected that a fault exists on the boiler
then is MUST NOT BE USED until the fault has been
corrected by a CORGI registered installer, or in IE a
competent person.

WARNING

This appliance MUST be efficiently earthed.

MAINTENANCE

The appliance should be serviced at least once a year by a
CORGI registered installer, or in IE a competent person.

CLEANING OUTER CASING

For normal cleaning simply dust with a dry cloth.  To remove
stubborn marks and stains use a damp cloth and mild
detergent.

DO NOT use abrasive cleaning materials.

1

2

4

3

5

7

6

S

T

O

R

E

M

O

D

E

R

E

S

E

T

S

T

E

P

Reset

D

i

sp

l

ay

Mode

Step

Store

+ -

On

/

Off

 

sw

i

tch

Reset

 

buttons

 

for

 

the

d

i

fferent

 

modu

l

es

Operat

i

on

 

and

 i

nd

i

cat

i

ons

 

on

 

the

 

d

i

sp

l

ay

 

(examp

l

e

 

w

i

th

 

7

 

modu

l

es)

Pressure

gauge

i

ma

 

578

4

All CORGI registered installers carry a CORGI ID card, and have a registration number. Both should be recorded in
your 

Benchmark 

Log Book.  You can check your installer by calling CORGI direct on 01563 72300

2

Summary of Contents for Imax Plus II F90

Page 1: ...IND When replacing any part on this appliance use only spare parts that you can be assured conform to the safety and performance specification that we require Do not use reconditioned or copy parts th...

Page 2: ...the boiler 6 Do not turn off the boiler if it is to be left unattended in frosty weather 7 The boiler must not be operated without the casing correctly fitted 8 If it is known or suspected that a fau...

Page 3: ...breviation for parameter is displayed In this mode it is possible to change the settings of the boiler control module By pressing the mode key again DATA mode is displayed In this mode it is possible...

Page 4: ...displays when in DATA mode It stores when in PARA mode it in creases or decreases the displ ayed value Reset the boiler Th e parameter number is not displayed By pressing step By pressing mode By pres...

Page 5: ...s off System pump runs continuously 11 CH DHW are both on 12 CH DHW are both on System pump runs continuously 11 1 6 0 Maximum CH Flow Temperature Setpoint degC S T E P 30 90 80 3 8 0 5 DATA MODE By p...

Page 6: ...a separate frost thermostat should be fitted BOILER LOCKOUTS When a burner module locks out the corresponding red reset button illuminates on the fascia If the entire boiler locks out an error messag...

Page 7: ...II Users 7...

Page 8: ...x 01482 448858 Registration No London 322 137 Ideal Stelrad Group pursues a policy of continuing improvement in the design and performance of its products The right is therefore reserved to vary speci...

Reviews: