4
mexico HE
-
Installation & Servicing
GENERAL
Boiler Size
hE15 hE18 hE24 hE30 hE36 hE15-24
hE30-36
max max max max max min min
Input ‘Q’ Nett CV kW (Btu/h)
15.1 (51,500) 18.7 (63,800) 24.4 (83,300) 30.7 (104,700) 37.5 (128,000) 9.1 (31,000)
10.6 (36,200)
Gross CV kW (Btu/h)
16.8 (57,200) 20.7 (70,800) 27.1 (92,500) 34.0 (116,000) 41.6 (142,000) 10.1 (34,400) 11.8 (40,300)
Gas Consumption l/s (cu.ft/h)
0.43 (54.7)
0.53 (68.0)
0.70 (89.7)
0.88 (111.9) 1.07 (136.0)
0.26 (33.3)
0.30 (38.4)
Output ‘P’ 70
o
c Mean Water temp. kW (Btu/h)
14.6 (50,000) 18.2 (62,300) 23.4 (80,000) 30.1 (102,700) 37.0 (126,200) 8.8 (30,000)
10.6 (36,200)
40
o
c Mean Water temp. kW (Btu/h)
15.5 (53,000) 19.2 (65,700) 25.1 (85,700) 32.8 (111,800) 39.8 (135,800) 9.6 (32,800)
11.4 (38,900)
Seasonal efficiency (SEDBUK) *
Band A [90.4]%
[90.3]%
[90.2]%
[90.4]%
[90.7]%
-
-
NOx classification
Class 5
CAUTION.
To avoid the possibility of injury during the installation, servicing or cleaning
of this appliance, care should be taken when handling edges of sheet steel components.
Note.
Gas consumption is calculated using a calorific value of
38.7 MJ/m
3
(1038 Btu/ft
3
) gross or 34.9 MJ/m
3
(935 Btu/ft
3
)
nett. To obtain the gas consumption at a different calorific
value:-
a.
For
l/s - divide the gross heat input (kW) by the gross
C.V. of the gas (MJ/m
3
)
b.
For ft
3
/h - divide the gross heat input (Btu/h) by the
gross C.V. of the gas (Btu/ft
3
)
c.
For m
3
/h
- multiply l/s by 3.6
Key to symbols
gB
= United Kingdom
IE
= Ireland
(Countries of destination)
pMs
= Maximum operating pressure of water
C
13
C
33
=
A room sealed appliance designed for connection
via ducts to a horizontal or vertical terminal which admits
fresh air to the burner and discharges the products of
combustion to the outside through orifices which, in
this case, are concentric. The fan is up stream of the
combustion chamber.
I
2h
= An appliance designed for use on 2nd Family gas, Group
H only.
*
The value is used in the UK Government’s Standard Assessment Procedure (SAP) for energy rating of dwellings.
The test data from which it has been calculated have been certified by a notified body.
Table 1 - general Data
Table 2 - performance Data
Boiler Size
hE15 hE18 hE24 hE30 hE36
Gas Supply Connection
in. BSP
Rc
1
/
2
Rc
1
/
2
Rc
1
/
2
Rc
1
/
2
Rc
1
/
2
Flow and Return Connections
22mm copper 22mm copper
22mm copper 22mm copper 22mm copper
MAxIMUM Static Water Head
m (ft.)
30.5 (100)
30.5 (100)
30.5 (100)
30.5 (100)
30.5 (100)
MINIMUM Static Water Head
m (ft.)
0.45 (1.5)
0.45 (1.5)
0.45 (1.5)
0.45 (1.5)
0.45 (1.5)
Electrical Supply
230V - 50Hz
230V - 50Hz
230V - 50Hz
230V - 50Hz
230V - 50Hz
Power Consumption
38W
38W
38W
42W
42W
Fuse Rating
External : 3A internal T3.15A L250V
Water Content
litre (gal.)
2.0 (0.44)
2.0 (0.44)
2.0 (0.44)
4.7 (1.0)
4.7 (1.0)
Packaged Weight
kg. (lb.)
55.4 (122.4)
55.4 (122.4)
55.4 (122.4)
69 (152)
69 (152)
Maximum Inst Weight
kg. (lb.)
52 (114.6)
52 (114.6)
52 (114.6)
68 (150)
68 (150)
Boiler Size
Height mm (in.)
850 (33.5)
850 (33.5)
850 (33.5)
850 (33.5)
850 (33.5)
Width mm (in.)
450 (17.7)
450 (17.7)
450 (17.7)
450 (17.7)
450 (17.7)
Depth mm (in.)
530 (20.9)
530 (20.9)
530 (20.9)
530 (20.9)
530 (20.9)
Gas Type
I2H-G20
I2H-G20
I2H-G20
I2H-G20
I2H-G20
Gas Supply Pressure
20mb
20mb
20mb
20mb
20mb
Flue duct diameter
mm (in.)
100 (4)
100 (4)
100 (4)
100 (4)
100 (4)
Flue horizontal duct length (max)
m
6
6
6
3
3
Summary of Contents for he15
Page 2: ...2 mexico HE Installation Servicing...
Page 50: ......