13
mexico HE
-
Installation & Servicing
General
safety valve setting
3.0 bar
2.5 bar
2.0 bar
Vessel charge and initial
0.5 1.0 1.5 0.5 1.0 1.5 0.5 1.0
system pressure
bar bar bar bar bar bar bar bar
Total water content of system
Expansion vessel volume litres
litres
25
2.1 2.7 3.9 2.3 3.3 5.9 2.8 5.0
50
4.2 5.4 7.8 4.7 6.7 11.8 5.6
10.0
75
6.3 8.2 11.7 7.0 10.0 17.7 8.4 15.0
100
8.3 10.9 15.6 9.4 13.4 23.7 11.3 20.0
125
10.4 13.6 19.5 11.7 16.7 29.6 14.1 25.0
150
12.5 16.3 23.4 14.1 20.1 35.5 16.9 30.0
175
14.6 19.1 27.3 16.4 23.4 41.4 19.7 35.0
200
16.7 21.8 31.2 18.8 26.8 47.4 22.6 40.0
225
18.7 24.5 35.1 21.1 30.1 53.3 25.4 45.0
250
20.8 27.2 39.0 23.5 33.5 59.2 28.2 50.0
275
22.9 30.0 42.9 25.8 36.8 65.1 31.0 55.0
300
25.0 32.7 46.8 28.2 40.2 71.1 33.9 60.0
Multiplying factors for
other system volumes
0.0833 0.109 0.156 0.094 0.134 0.237 0.113 0.20
8 sEALED sysTEM REqUIREMENTs - continued
9 WATER TREATMENT
The mexico hE boiler range have an ALUMINIUM alloy
heat exchanger
IMpORTANT.
The application of any other treatment
to this product may render the guarantee of Ideal
stelrad group invalid.
Ideal stelrad group
recommend water treatment in
accordance with the
Benchmark
Guidance Notes on Water
Treatment in Central Heating systems.
If water treatment is used
Ideal stelrad group
recommend
only the use of Scalemaster Gold 100,
FERNOx, MB-1,
ADEy MC1
or
SENTINEL-x100
inhibitors and associated water
treatment products, which must be used in accordance with
the manufacturers’ instructions.
Notes.
1.
It is most important that the correct concentration of the water
treatment products is maintained in accordance with the
manufacturers’ instructions.
2.
If the boiler is installed in an existing system any unsuitable
additives MUST be removed by thorough cleansing. BS
7593:2006 details the steps necessary to clean a domestic
heating system.
3.
In hard water areas, treatment to prevent lime scale may be
necessary - however the use of artificially softened water is
NOT permitted.
4.
Under no circumstances should the boiler be fired before the
system has been thoroughly flushed.
For further information contact:
Fernox Cookson Electronics
Forsyth Road
Sheerwater
Woking
Surrey GU21 5RZ
+44 (0) 870 601 5000
Sentinel Performance Solutions
The Heath Business & Technical Park
Runcorn
Cheshire WA7 4Qx
Tel: 0800 389 4670
www.sentinel-solutions.net
Scalemaster Water Treatment Products
Emerald Way
Stone
Staffordshire ST15 0SR
Tel: +44 (0) 1785 811636
Calmag Ltd.
Unit 3-6, Crown Works
Bradford Road
Sandbeds, Keighley
West yorkshire BD20 5LN
Tel: +44 (0) 1535 210 320
Adey Professional Heating Solutions
Gloucester Road,
Cheltenham GL51 8NR
Tel: +44 (0) 1242 546700