25
mexico HE
-
Installation & Servicing
InstallatIon
FLUE OUTLET
part No. Description
60/100 quantity
hE15 hE18 hE24 hE30 hE36
n/a
Maximum Flue Length (m)
8
8
8
5
5
201 180 Flue ext. 60/100
7
7
7
6
6
201 189 Terminal Vertical Roof 60/100 1
1
1
1
1
152 258 Weather Collar Pitched Roof
1
1
1
1
1
152 259 Weather Collar Flat Roof
1
1
1
1
1
201 182 90
o
Elbow Kit (60/100)
4
4
4
2
2
201 183 45
o
Elbow Kit (60/100)
4
4
4
2
2
201 869 Vertical Connector
1
1
1
1
1
31 FLUE TERMINAL pOsITION
610 mm
min.
ex7531
610 mm
min.
ex7532
The terminal should be positioned so that products of
combustion can safely disperse at all times.
pluming may occur at the termination so, where
possible, terminal positions where this could cause a
nuisance should be avoided.
Minimum dimensions are shown below
mxhe7686
mxhe7687
32 FLUE ARRANgEMENT
Note.
The equivalent flue length resistance of the 90
o
elbow kit
(60/100) is 1m and the 45
o
elbow kit (60/100) is 0.75m.
Terminal position
Minimum Dimension
Directly below an opening,
air brick, windows, etc.
300 mm
Below plastic / painted gutters
300 mm
Painted surface
300 mm
Below eaves or balcony
500 mm
Below velux windows
2000mm
Above or side of velux windows
600mm
rf8392
Note.
The equivalent flue length resistance of the elbow kits are:
90
o
elbow kit = 1m
45
o
elbow kit = 0.6m
RF9807
A
A
B
A
A = 600mm
B = 2000mm
The flue terminal shall not penetrate the shaded area of the roof